Description: Magenta image drum motor rotation error
Remedy: Perform the drum-motors component test in the DIAGNOSTICS menu. If the message persists, replace the magenta drum motor.
Code: 59.63
Display: 59.63 ERROR
Description: Yellow image drum motor rotation error
Remedy: Perform the drum-motors component test in the DIAGNOSTICS menu. If the message persists, replace the yellow drum motor.
Code: 59.90
Display: 59.90 ERROR
Description: ITB motor startup error
Remedy: Reconnect the connector J14 of the ITB motor and the connector J140 on the DC controller PCA. Perform the ITB motor drive component test to verify that the ITB motor is functioning properly. If the message persists, replace the ITB motor.
Code: 59.A0
Display: 59.A0 ERROR
Description: ITB motor rotation error.
Remedy: Use the component test to activate the ITB motor. If the motor does not function, replace the motor.
Code: 59.B0
Display: 59.B0 CLEANING MOTOR ERROR
Description: The residual-toner feed motor has failed.
Remedy: 1. Check the toner collection unit. If the unit is full, replace it. NOTE: Toner can clog the feed motor if the toner collection unit is full. 2. Reconnect the residual-toner feed motor connector J63 and connector J155 on the DC controller PCA. 3. Replace the residual-toner feed motor.
Code: 59.C0
Display: 59.C0 ERROR
Description: Developer alienation motor rotation error
Remedy: 1. Reconnect intermediate connector J87 of the developing disengagement sensor, connector J112 on the DC controller PCA, connector J38 of the developing disengagement motor, and the connector J261 on the high-voltage power supply D PCA. 2. Run the sensor test in the sensor monitor mode to verify that the developing disengagement sensor is functioning properly. If it is not, replace the main-drive assembly. 3. Run the developing unit disengagement drive test to verify that the disengagement mechanism is functioning properly. If it is not, replace the developing disengagement motor.
Code: 59.F0
Display: 59.F0 ERROR
Description: Transfer alienation failure
Remedy: 1. Verify that the ITB is installed. 2. Reconnect the primary-transfer disengagement sensor J19, and connector J128 on the DC controller PCA . 3. Run the sensor test in the sensor monitor mode to verify that the primary transfer disengagement sensor is functioning properly. If not, replace the primary transfer disengagement sensor. 4. Perform the alienation drive component test in the DIAGNOSTICS menu. If not, replace the fuser motor.
Code: 60.02
Display: 60.02 ERROR
Description: Tray 2 is not lifting correctly.
Remedy: 1. Reconnect connector J115 on the DC controller PCA and the intermediate connector J58. 2. Run the sensor test in sensor monitor mode to verify that the cassette media stack surface sensor is functioning properly. If it is not, replace the pickup assembly. 3. Reconnect connector J56 of the lifter motor. Also check J107 on the DC controller PCA. 4. If the message persists, replace the lifter drive assembly.