Các lỗi thường gặp

Code :
  • Code: 1330
  • Description: Scan-Axis Motor Temperature Sensor Error
    The Scan-Axis Motor Temperature Sensor has detected abnormal temperatures (-22.5C or lower or 150C or higher).
  • Remedy: • Make sure that the Scan-Axis Motor Temperature Sensor is connected correctly and the cable is not damaged. • Replace the Scan-Axis Motor Cooling Fan. • Replace the Main PCA.
  • Code: 140x
  • Description: Heater Temperature Error
    Temperature read by the Heater Temperature Sensor is abnormal (lower than -20C or higher than 200C). x = 1: Front heater. x = 2: Center Platen. x = 3: Rear Heater.
  • Remedy: • Make sure that the failing Heater is connected correctly to the Main PCA. Make sure that the cables are not damaged. • Replace the failing Heater. • Replace the Main PCA.
  • Code: 141x
  • Description: Heater Error (High Temperature)
    Temperature read by the Heater Temperature Sensor is above 65C). x = 1: Front heater. x = 2: Center Platen. x = 3: Rear Heater.
  • Remedy: • If the Printer is installed in a high temperature environment, move the Printer to an area where the operating temperature is much lower. • Make sure that the failing Heater is connected correctly to the Main PCA. Make sure that the cables are not damaged. • Replace the failing Heater. • Replace the Main PCA.
  • Code: 143x
  • Description: Heater Error (Insufficient Heating)
    The Heater is not heated to a specified temperature even after 30 minutes have passed. x = 1: Front heater. x = 2: Center Platen. x = 3: Rear Heater.
  • Remedy: • If the Printer is installed in a low temperature environment, move the Printer to an area where the operating temperature is much higher. • Check that the AC Voltage being used is the one selected on the Heater Voltage Setting Switch. • Make sure that the failing Heater is connected correctly to the Main PCA. Make sure that the cables are not damaged. • Replace the Heater Relay Board. • Replace the failing Heater. • Replace the Main PCA.
  • Code: 144x
  • Description: Heater Error
    No heater sequence interrupt.
  • Remedy: • Make sure that all the cables are correctly connected to the Heater Relay Board. Make sure that the cables are not damaged. • Replace the Heater Relay Board. • Replace the Main PCA.
  • Code: 2000 ... 6000
  • Description: Firmware Logic Error
    A logic error has occurred in the Firmware program.
  • Remedy: • Reinstall the Firmware or upgrade to the latest version (if available). • Replace the Main PCA.