Description: The Front Panel watchdog timer has expired
Causes: The Front Panel watchdog timer has expired.
Remedy: 1. Switch the power off at the rear of the printer, wait briefly, then switch it back on again. 2. Upgrade the firmware.
Code: 08:04.1
Description: ASSERT in Front Panel code
Causes: ASSERT in Front Panel code.
Remedy: 1. Press Enter and continue. 2. Update the firmware.
Code: 08:08
Description: ASSERT in Front Panel code
Causes: ASSERT in Front Panel code.
Remedy: Switch the power off at the rear of the printer, wait briefly, then switch it back on again.
Code: 08:11
Description: A Front Panel application has died
Causes: A Front Panel application has died.
Remedy: 1. Switch the power off at the rear of the printer, wait briefly, then switch it back on again. 2. Replace the Front Panel.
Code: 11:10
Description: Connection problem with the Trailing Cable
Causes: The Trailing Cable does not seem to be connected.
Remedy: 1. Check that the Trailing Cable is not damaged. 2. Check that the Trailing Cable is correctly connected to the Carriage PCA, Interconnect PCA, and Main PCA. 3. Replace the Ink Supply Tubes and Trailing Cable
Code: 14.31:10
Description: Pinch Power regulator V null and no fault
Causes: Pinch Power regulator V null and no fault.
Remedy: 1. Switch the power off at the rear of the printer, wait briefly, then switch it back on again. 2. Run the Monitoring Sine-waves and Resistances diagnostic test. 3. Replace the control cables to the sine-wave converter.
Code: 14.32:01
Description: Pinch Power regulator V null and faulty
Causes: Pinch Power regulator V null and faulty.
Remedy: 1. Switch the power off at the rear of the printer, wait briefly, then switch it back on again. 2. Run the Monitoring Sine-waves and Resistances diagnostic test. 3. Check the Residual Current Circuit Breakers. 4. Check the input voltage.
Code: 14.33:01
Description: Pinch Power regulator V lower than 140
Causes: Pinch Power regulator V lower than 140.
Remedy: 1. Switch the power off at the rear of the printer, wait briefly, then switch it back on again. 2. Check the input voltage. 3. Run the Monitoring Sine-waves and Resistances diagnostic test.