Description: Connection problem with the Trailing Cable
Causes: The Trailing Cable does not seem to be connected.
Remedy: 1. Check that the Trailing Cable is not damaged. 2. Check that the Trailing Cable is correctly connected to the Carriage PCA, Interconnect PCA, and Main PCA. 3. Replace the Ink Supply Tubes and Trailing Cable
Description: Pinch Power regulator V null and no fault
Causes: Pinch Power regulator V null and no fault.
Remedy: 1. Switch the power off at the rear of the printer, wait briefly, then switch it back on again. 2. Run the Monitoring Sine-waves and Resistances diagnostic test. 3. Replace the control cables to the sine-wave converter.
Description: Pinch Power regulator V null and faulty
Causes: Pinch Power regulator V null and faulty.
Remedy: 1. Switch the power off at the rear of the printer, wait briefly, then switch it back on again. 2. Run the Monitoring Sine-waves and Resistances diagnostic test. 3. Check the Residual Current Circuit Breakers. 4. Check the input voltage.
Description: Pinch Power regulator V lower than 140
Causes: Pinch Power regulator V lower than 140.
Remedy: 1. Switch the power off at the rear of the printer, wait briefly, then switch it back on again. 2. Check the input voltage. 3. Run the Monitoring Sine-waves and Resistances diagnostic test.