Các lỗi thường gặp

Code :
  • Code: 14.47:10
  • Description: Pinch Power regulator OverTemp
  • Causes: Pinch Power regulator OverTemp.
  • Remedy: 1. Switch the power off at the rear of the printer, wait briefly, then switch it back on again. 2. Run the Monitoring Sine-waves and Resistances diagnostic test. 3. Check cable connections. 4. Check that the input voltage is within specifications. 5. Replace the sine-wave converter.
  • Code: 14.48:10
  • Description: Pinch Power regulator overvoltage or short-circuit
  • Causes: Pinch Power regulator overvoltage or short-circuit.
  • Remedy: 1. Switch the power off at the rear of the printer, wait briefly, then switch it back on again. 2. Run the Monitoring Sine-waves and Resistances diagnostic test. 3. Check cable connections. 4. Check that the input voltage is within specifications. 5. Replace the sine-wave converter.
  • Code: 14.49:10
  • Description: Pinch sine-wave converter failure
  • Causes: Pinch sine-wave converter failure.
  • Remedy: 1. Switch the power off at the rear of the printer, wait briefly, then switch it back on again. 2. Replace the sine-wave converter.
  • Code: 14.51:10
  • Description: Overdrive power regulator V null and no fault
  • Causes: Overdrive power regulator V null and no fault.
  • Remedy: 1. Switch the power off at the rear of the printer, wait briefly, then switch it back on again. 2. Run the Monitoring Sine-waves and Resistances diagnostic test. 3. Replace the control cables to the sine-wave converter.
  • Code: 14.52:01
  • Description: Overdrive power regulator V null and fault
  • Causes: Overdrive power regulator V null and fault.
  • Remedy: 1. Switch the power off at the rear of the printer, wait briefly, then switch it back on again. 2. Run the Monitoring Sine-waves and Resistances diagnostic test. 3. Check the Residual Current Circuit Breakers. 4. Check the input voltage.
  • Code: 14.53:01
  • Description: Overdrive power regulator V lower than 140
  • Causes: Overdrive power regulator V lower than 140.
  • Remedy: 1. Switch the power off at the rear of the printer, wait briefly, then switch it back on again. 2. Check the input voltage. 3. Run the Monitoring Sine-waves and Resistances diagnostic test.
  • Code: 14.54:01
  • Description: Overdrive power regulator V lower than 180
  • Causes: Overdrive power regulator V lower than 180.
  • Remedy: 1. Switch the power off at the rear of the printer, wait briefly, then switch it back on again. 2. Check the input voltage. 3. Run the Monitoring Sine-waves and Resistances diagnostic test.
  • Code: 14.55:01
  • Description: Overdrive power regulator V higher than Vmax
  • Causes: Overdrive power regulator V higher than Vmax.
  • Remedy: 1. Switch the power off at the rear of the printer, wait briefly, then switch it back on again. 2. Check the input voltage. 3. Run the Monitoring Sine-waves and Resistances diagnostic test.
‹ First  < 2 3 4 5 6 7 8 >  Last ›
popup

Số lượng:

Tổng tiền:

Danh mục