Remedy: 1. Switch the power off at the rear of the printer, wait briefly, then switch it back on again. 2. Replace the Vacuum Fan SVS side.
Code: 43:11
Description: Vacuum Fan not connected
Causes: A Vacuum Fan does not seem to be connected.
Remedy: 1. Check the cable connections between the Mini Interconnect PCA and Eolas SVS side. 2. Replace Eolas. 3. Replace the Mini Interconnect PCA.
Code: 44.1:01
Description: Waste Management cable not connected
Causes: The waste management system cable is disconnected.
Remedy: 1. Check the connections between the Waste Management PCA and the printer. 2. Check the connections to the Interconnect PCA. 3. Check that the cable of the waste management system is correctly connected to the connector at the EBOX (this check can be done by the customer). This is the most probable cause. 4. Replace the Waste Management module (this part can be changed by the customer). 5. Check that the cable from the EBOX to the Interconnect PCA is correctly connected. 6. Check that the cables going from the Interconnect PCA to the PrintMech PCA are correctly connected. 7. Replace the Interconnect PCA. 8. Replace the PrintMech PCA.
Code: 44.2:01
Description: Waste management switch open
Causes: At least one of the switches of the waste management sub-assembly is in open status.
Remedy: 1. Check that the aerosol filter door is correctly closed (this can be done by the customer). 2. Check that the waste management ink tube is correctly inserted in the waste management subassembly (this can be done by the customer). 3. Replace the Waste Management module (this part can be changed by the customer). This is the most likely solution. 4. Check that the cable of the waste management system is correctly connected to the connector at the EBOX (this check can be done by the customer). 5. Check that the cable from the EBOX to the Interconnect PCA is correctly connected. 6. Check that the cables going from the Interconnect PCA to the PrintMech PCA are correctly connected. 7. Replace the Interconnect PCA. 8. Replace the PrintMech PCA.
Causes: There is a short-circuit in the waste management system cable, and maybe also in the Interconnect PCA.
Remedy: 1. Replace the Waste Management module (this part can be changed by the customer). This is the most likely solution. 2. Check that the cable of the waste management system is correctly connected to the connector at the EBOX (this check can be done by the customer). 3. Check that the cable from the EBOX to the Interconnect PCA is correctly connected. 4. Check that the cables going from the Interconnect PCA to the PrintMech PCA are correctly connected. 5. Replace the Interconnect PCA. 6. Replace the PrintMech PCA.
Code: 44.4:01
Description: Problem in the waste management feedback signal
Causes: There is a problem with the feedback signal from the waste management system.
Remedy: 1. Check that the cable of the waste management system is correctly connected to the connector at the EBOX (which can be done by the customer). This is the most probable failure. 2. Replace the Waste Management module (which can be done by the customer). 3. Check that the cable from the EBOX to the Interconnect PCA is correctly connected. 4. Check that the cables going from the Interconnect PCA to the PrintMech PCA are correctly connected. 5. Replace the Interconnect PCA. 6. Replace the PrintMech PCA.
Code: 44:10
Description: There is a problem with the Aerosol Fan
Causes: There is no feedback signal from the Waste Management Aerosol Fan.
Remedy: 1. Replace the Waste Management module (which can be done by the customer). This is the most probable failure. 2. Check that the cable of the waste management system is correctly connected to the connector at the EBOX (which can be done by the customer). 3. Check that the cable from the EBOX to the Interconnect PCA is correctly connected. 4. Check that the cables going from the Interconnect PCA to the PrintMech PCA are correctly connected. 5. Replace the Interconnect PCA. 6. Replace the PrintMech PCA.