Display: 58.00.0Y Error To continue turn off then on
Description: A sensor error has occurred.
LVPS failure
Remedy: 1. Turn the product off. 2. If this part has been removed or replace, check the connector (J50) on the LVPS, and then check the connector (J85 and J95) on the DC controller PCA. 3. If the error persists, replace the LVPS.
Code: 58.00.05
Display: 58.00.0Y Error To continue turn off then on
Description: A sensor error has occurred.
Environmental sensor (TH3) failure
Remedy: 1. Turn the product off. 2. If this part has been removed or replace, check the connector (J63) on the DC controller PCA. 3. If the error persists, replace the environmental sensor (TH3).
Code: 59.00.20
Display: 59.00.YY error To continue turn off then on
Description: A motor error has occurred. . YY = 00 Paper path malfunction
Feed motor (M101) failure (start-up or rotational)
Remedy: 1. Reconnect the connector (J191) on the feed motor and the connector (J91) on the DC controller PCA. 2. Use the feed motor (M101) drive test in the Component test to verify that the motor is properly functioning. If is not, replace the feed motor (M101).
Code: 59.00.30
Display: 59.00.YY error To continue turn off then on
Description: A motor error has occurred. . YY = 00 Paper path malfunction
Feed motor (M101) failure (start-up or rotational)
Remedy: 1. Reconnect the connector (J191) on the feed motor and the connector (J91) on the DC controller PCA. 2. Use the feed motor (M101) drive test in the Component test to verify that the motor is properly functioning. If is not, replace the feed motor (M101).
Code: 59.00.40
Display: 59.00.YY error To continue turn off then on
Description: A motor error has occurred. . YY = 00 Paper path malfunction
Fuser motor (M299) failure (start-up or rotational)
Remedy: 1. Reconnect the connector (J221) on the feed motor and the connector (J89) on the DC controller PCA. 2. Use the fuser motor (M299) drive test in the Component test to verify that the motor is properly functioning. If it is not, replace the fuser motor (M299).
Code: 59.00.50
Display: 59.00.YY error To continue turn off then on
Description: A motor error has occurred. . YY = 00 Paper path malfunction
Fuser motor (M299) failure (start-up or rotational)
Remedy: 1. Reconnect the connector (J221) on the feed motor and the connector (J89) on the DC controller PCA. 2. Use the fuser motor (M299) drive test in the Component test to verify that the motor is properly functioning. If it is not, replace the fuser motor (M299).
Code: 59.00.60
Display: 59.00.YY error To continue turn off then on
Description: A motor error has occurred. . YY = 00 Paper path malfunction
Drum motor (M102) failure (start-up or rotational)
Remedy: 1. Reconnect the connector (J187) on the drum motor and the connector (J87) on the DC controller PCA. 2. Use the drum motor (M102) drive test in the Component test to verify that the motor is properly functioning. If it is not, replace the drum motor (M102).
Code: 59.00.70
Display: 59.00.YY error To continue turn off then on
Description: A motor error has occurred. . YY = 00 Paper path malfunction
Drum motor (M102) failure (start-up or rotational)
Remedy: 1. Reconnect the connector (J187) on the drum motor and the connector (J87) on the DC controller PCA. 2. Use the drum motor (M102) drive test in the Component test to verify that the motor is properly functioning. If it is not, replace the drum motor (M102).