Description: Printmech: 42V to Paper motor failure
Causes: The 42V cable from Printmech to Paper motor has a problem Printmech PCA is damaged.
Remedy: Call agent: • Restart the printer. Service engineer: 1. Check the Printmech to paper motor cable. 2. Check the paper motor. 3. Check the Printmech PCA.
Code: 12.16:10
Description: Printmech: 42V to Rewinder failure
Causes: The 42V cable from Printmech to Rewinder has a problem Printmech PCA is damaged.
Remedy: Call agent: • Restart the printer. Service engineer: 1. Check the Printmech to Rewinder cable. 2. Check the Rewinder. 3. Check the Printmech PCA.
Code: 12.17:10
Description: Printmech: 42V to Scan motor failure
Causes: The 42V cable from Printmech to Scan motor has a problem Printmech PCA is damaged.
Remedy: Call agent: • Restart the printer. Service engineer: 1. Check the Printmech to Scan motor cable. 2. Check the Scan motor. 3. Check the Printmech PCA.
Code: 12.18:10
Description: Printmech: 42V to SOL slit solenoid failure
Causes: The 42V cable from Printmech to SOL slit solenoid has a problem Printmech PCA is damaged.
Remedy: Call agent: • Restart the printer. Service engineer: 1. Check the Printmech to SOL slit solenoid cable. 2. Check the slit solenoid. 3. Check the Printmech PCA.
Code: 12.19:10
Description: Printmech: 5V line failure
Causes: The 5V cable from Printmech to PSU has a problem Printmech PCA is damaged PSU is damaged.
Remedy: Call agent: • Restart the printer.
Code: 12.1:10
Description: The 12V provided from Printmech to Curing module PCA are out of range (10,8V to 13,2V)
Causes: One or more of the components powered by the 12V at the Curing Control PCA are causing a short circuit. The 12V cable from Printmech to the Curing Control PCA has a problem.
Remedy: Call agent: • Restart the printer. Service engineer: 1. Check the Printmech cable to the Curing module PCA. 2. Check the Printmech PCA.
Code: 12.20:10
Description: Printmech: 12V to Curing module PCA open circuit
Causes: The 12V cable from Printmech to Curing Control PCA has a problem Printmech PCA is damaged.
Remedy: Call agent: • Restart the printer. Service engineer: 1. Check cable the Printmech to Curing module cable. 2. Check the Printmech PCA.
Code: 12.21:10
Description: Printmech: 24V to Curing module PCA open circuit
Causes: The 24V cable from Printmech to Curing Control PCA has a problem Printmech PCA is damaged.
Remedy: Call agent: • Restart the printer. Service engineer: 1. Check the Printmech to Curing module PCA cable. 2. Check the Printmech PCA.