Thương hiệu phân phối chính hãng
Giỏ hàng

Mã lỗi HP Latex 310 — Trang 5/32

Code: 12.22:10

Description: Printmech: 12V to Vapor Removal PCA open circuit
Causes: The 12V cable from Printmech to Vapor Removal PCA has a problem Printmech PCA is damaged.
Remedy: Call agent: • Restart the printer. Service engineer: 1. Check the Printmech to Vapor Removal PCA cable. 2. Check the Printmech PCA.

Code: 12.23:10

Description: Printmech: 24V to Vapor Removal PCA open circuit
Causes: The 24V cable from Printmech to Vapor Removal PCA has a problem Printmech PCA is damaged.
Remedy: Call agent: • Restart the printer. Service engineer: 1. Check the Printmech to Vapor Removal PCA cable. 2. Check the Printmech PCA.

Code: 12.24:10

Description: Printmech: 12V to ISS, DD, 42Vdc motor drivers, Top cover fans and PZ fans open circuit
Causes: The 12V cable from Printmech to ISS, Interconnect and PZ fans has a problem Printmech PCA is damaged.
Remedy: Call agent: • Restart the printer. Service engineer: 1. Check the Printmech to ISS, Interconnect, and PZ fans cables. 2. Check the Printmech PCA.

Code: 12.25:10

Description: Printmech: 42V to Carriage PCA open circuit
Causes: The 42V cable from Printmech to Carriage PCA has a problem Printmech PCA is damaged.
Remedy: Call agent: • Restart the printer. Service engineer: 1. Check the Printmech to Carriage PCA cable. 2. Check the Printmech PCA.

Code: 12.26:10

Description: Printmech: Hannibal1 24V open circuit. Check APS relief valve, SVS motor and Rack engage motor
Causes: The 24V cable from Printmech to Interconnect has a problem Printmech PCA is damaged.
Remedy: Call agent: • Restart the printer. Service engineer: 1. Check the APS relief valve, SVS motor and Rack engage motor. 2. Check the Printmech PCA.

Code: 12.27:10

Description: Printmech: Hannibal2 24V open circuit. Check Spit-on roller motor and Primer motor
Causes: The 24V cable from Printmech to Interconnect has a problem Printmech PCA is damaged.
Remedy: Call agent: • Restart the printer. Service engineer: 1. Check the Spit-on roller motor and Primer motor. 2. Check the Printmech PCA.

Code: 12.28:10

Description: Printmech: Hannibal3 24V open circuit. Check Inner lights array 1
Causes: The 24V cable from Printmech to Inner lights array 1 has a problem Printmech PCA is damaged.
Remedy: Call agent: • Restart the printer. Service engineer: 1. Check the Inner lights array 1. 2. Check the Printmech PCA.

Code: 12.29:10

Description: Printmech: Hannibal4 24V open circuit. Check Inner lights array 2
Causes: The 24V cable from Printmech to Inner lights array 2 has a problem Printmech PCA is damaged.
Remedy: Call agent: • Restart the printer. Service engineer: 1. Check the Inner lights array 2. 2. Check the Printmech PCA.
Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin
Đăng ký nhận bản tin
Nhận ưu đãi sớm nhất khi chương trình diễn ra

Đăng ký nhận bản tin

Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này. Chính sách cookie