Các lỗi thường gặp

Code :
  • Code: 12.22:10
  • Description: Printmech: 12V to Vapor Removal PCA open circuit
  • Causes: The 12V cable from Printmech to Vapor Removal PCA has a problem Printmech PCA is damaged.
  • Remedy: Call agent: • Restart the printer. Service engineer: 1. Check the Printmech to Vapor Removal PCA cable. 2. Check the Printmech PCA.
  • Code: 12.23:10
  • Description: Printmech: 24V to Vapor Removal PCA open circuit
  • Causes: The 24V cable from Printmech to Vapor Removal PCA has a problem Printmech PCA is damaged.
  • Remedy: Call agent: • Restart the printer. Service engineer: 1. Check the Printmech to Vapor Removal PCA cable. 2. Check the Printmech PCA.
  • Code: 12.24:10
  • Description: Printmech: 12V to ISS, DD, 42Vdc motor drivers, Top cover fans and PZ fans open circuit
  • Causes: The 12V cable from Printmech to ISS, Interconnect and PZ fans has a problem Printmech PCA is damaged.
  • Remedy: Call agent: • Restart the printer. Service engineer: 1. Check the Printmech to ISS, Interconnect, and PZ fans cables. 2. Check the Printmech PCA.
  • Code: 12.25:10
  • Description: Printmech: 42V to Carriage PCA open circuit
  • Causes: The 42V cable from Printmech to Carriage PCA has a problem Printmech PCA is damaged.
  • Remedy: Call agent: • Restart the printer. Service engineer: 1. Check the Printmech to Carriage PCA cable. 2. Check the Printmech PCA.
  • Code: 12.26:10
  • Description: Printmech: Hannibal1 24V open circuit. Check APS relief valve, SVS motor and Rack engage motor
  • Causes: The 24V cable from Printmech to Interconnect has a problem Printmech PCA is damaged.
  • Remedy: Call agent: • Restart the printer. Service engineer: 1. Check the APS relief valve, SVS motor and Rack engage motor. 2. Check the Printmech PCA.
  • Code: 12.27:10
  • Description: Printmech: Hannibal2 24V open circuit. Check Spit-on roller motor and Primer motor
  • Causes: The 24V cable from Printmech to Interconnect has a problem Printmech PCA is damaged.
  • Remedy: Call agent: • Restart the printer. Service engineer: 1. Check the Spit-on roller motor and Primer motor. 2. Check the Printmech PCA.
  • Code: 12.28:10
  • Description: Printmech: Hannibal3 24V open circuit. Check Inner lights array 1
  • Causes: The 24V cable from Printmech to Inner lights array 1 has a problem Printmech PCA is damaged.
  • Remedy: Call agent: • Restart the printer. Service engineer: 1. Check the Inner lights array 1. 2. Check the Printmech PCA.
  • Code: 12.29:10
  • Description: Printmech: Hannibal4 24V open circuit. Check Inner lights array 2
  • Causes: The 24V cable from Printmech to Inner lights array 2 has a problem Printmech PCA is damaged.
  • Remedy: Call agent: • Restart the printer. Service engineer: 1. Check the Inner lights array 2. 2. Check the Printmech PCA.