Description: Printmech: 24V to Interconnect open circuit. Check TUR, Right aerosol fan and Primer valves
Causes: The 24V cable from Printmech to Interconnect PCA has a problem Printmech PCA is damaged.
Remedy: Call agent: • Restart the printer. Service engineer: 1. Check the Printmech to Interconnect cable. 2. Check the TUR, Right aerosol fan, and Primer valves. 3. Check the Printmech PCA.
Description: Printmech: 24V Misc open circuit. Check Air pumps and Primer valves switch
Causes: The 24V cable from Printmech to Air Pumps and Interconnect PCA has a problem Printmech PCA is damaged.
Remedy: Call agent: • Restart the printer. Service engineer: 1. Check the Printmech to Air Pumps and to primer valves switch cable. 2. Check the Air Pumps. 3. Check the Primer valves switch. 4. Check the Printmech PCA.
Description: Printmech: 24V to Printzone fans open circuit
Causes: The 24V cable from Printmech to Printzone fans has a problem Printmech PCA is damaged.
Remedy: Call agent: • Restart the printer. Service engineer: 1. Check the Printmech to Printzone fans cable. 2. Check the Printzone fans. 3. Check the Printmech PCA.
Description: Printmech: 24V to Vacuum fans open circuit
Causes: The 24V cable from Printmech to Vacuum fans has a problem Printmech PCA is damaged.
Remedy: Call agent: • Restart the printer. Service engineer: 1. Check the Printmech to Vacuum fans cable. 2. Check the Vacuum fans. 3. Check the Printmech PCA.
Description: Printmech: 42V to Paper motor open circuit
Causes: The 42V cable from Printmech to Paper motor has a problem Printmech PCA is damaged.
Remedy: Call agent: • Restart the printer. Service engineer: 1. Check the Printmech to Paper motor cable. 2. Check the paper motor. 3. Check the Printmech PCA.
Description: Printmech: 42V to Rewinder open circuit
Causes: The 42V cable from Printmech to Rewinder has a problem Printmech PCA is damaged.
Remedy: Call agent: • Restart the printer. Service engineer: 1. Check the Printmech to Rewinder cable. 2. Check the Rewinder. 3. Check the Printmech PCA.
Description: Printmech: 42V to Scan motor open circuit
Causes: The 42V cable from Printmech to Scan motor has a problem Printmech PCA is damaged.
Remedy: Call agent: • Restart the printer. Service engineer: 1. Check the Printmech to Scan motor cable. 2. Check the Scan motor. 3. Check the Printmech PCA.
Nhận ưu đãi sớm nhất khi chương trình diễn ra
Đăng ký nhận bản tin
Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này.
Chính sách cookie
Những cookie này là cần thiết để trang web hoạt động đúng cách.
Những cookie này giúp chúng tôi hiểu cách khách truy cập tương tác với trang web.
Những cookie này được sử dụng để cung cấp quảng cáo cá nhân hóa.