Các lỗi thường gặp

Code :
  • Code: 16.41:10
  • Description: Curing system: module 1 failure
  • Causes: Curing resistor 1 disconnected or damaged.
  • Remedy: Call agent: • Restart the printer. Service engineer: • Replace module 1.
  • Code: 16.42:10
  • Description: Curing system: module 2 failure
  • Causes: Curing resistor 2 disconnected or damaged.
  • Remedy: Call agent: • Restart the printer. Service engineer: • Replace module 2.
  • Code: 16.43:10
  • Description: Curing system: module 3 failure
  • Causes: Curing resistor 3 disconnected or damaged.
  • Remedy: Service engineer: • Replace module 3.
  • Code: 16.44:10
  • Description: Curing system: module 4 failure
  • Causes: Curing resistor 4 disconnected or damaged.
  • Remedy: Call agent: • Restart the printer. Service engineer: • Replace module 4.
  • Code: 16.50:03
  • Description: Curing system: pressure calibration error
  • Causes: Silent SE: If there's already a valid pressure calibration in NVM, and new calibration values are out of range, then FW will use the NVM values and show a silent SE in the printer log and service plot.
  • Remedy:
  • Code: 16.50:10
  • Description: Severe SE: Pressure calibration failure together with NVM values = 0 (failure at first startup)
  • Causes: Pressure calibration failure.
  • Remedy: Service engineer: • Check the tube (not kinked), and sensor cable. If they are OK, replace the sensor
  • Code: 16.51:01
  • Description: Curing system: pressure not reachable. Printer is limiting working pressure
  • Causes: Silent SE. Customer symptoms are: Slower thput, and/or Lack of curing Printer limiting working pressure. It might be due to: Target pressure too high for printer attitude environment, and/or curing fan degradation.
  • Remedy:
  • Code: 16.61:10
  • Description: Vapor removal system: vapor fans array 1 fault
  • Causes: Air Curtain and Printzone Heaters Control/Curing Control PCA (depending on SKU) to Air Curtain Fans, Cable Air Curtain Fans.
  • Remedy: Call agent: • Restart the printer. Service engineer: 1. Reseat/Replace Air Curtain and Printzone Heaters Control/Curing Control PCA to Air Curtain Fans Cable. 2. Check that all Air Curtain Fans rotate, and are unobstructed. 3. Reseat/Replace Air Curtain Fans.