Code :
- Code: 94:01
- Description: CLC failed because paper white point is out of valid range
- Causes: Paper white point is out of valid range.
- Remedy: Call agent: • Ensure the loaded substrate is white and there aren't spots on it.
- Code: 94:02
- Description: CLC failed, inconsistencies in measures detected
- Causes: Inconsistencies in CLC measures detected.
- Remedy: Call agent: 1. Check substrate type selection in front panel corresponds to actual substrate loaded. 2. Retry calibration.
- Code: 94:08
- Description: Color Calibration failed
- Causes: Color Calibration failed.
- Remedy: Call agent: • Try again or check user manual color calibration troubleshooting.
- Code: 94:10
- Description: CLC measures out of range
- Causes: Aerosol or other malfunction of Color Sensor prevents calibration.
- Remedy: Service engineer: 1. Retry calibration. 2. Replace SOL.
- Code: 98:03
- Description: Potential Print Quality problem. Detected too many nozzles out
- Causes: Check PH using the PH status plot.
- Remedy: Service engineer: • Use the printhead status plot to find out which printheads have a massive number of nozzles out, and replace them.