Description: Printmech: 42V to SOL slit solenoid open circuit
Causes: The 42V cable from Printmech to SOL slit solenoid has a problem Printmech PCA is damaged.
Remedy: Call agent: • Restart the printer. Service engineer: 1. Check the Printmech to SOL slit solenoid cable. 2. Check the slit solenoid. 3. Check the Printmech PCA.
Code: 12.38:10
Description: Printmech: 5V line open circuit
Causes: The 5V cable from Printmech to PSU has a problem Printmech PCA is damaged PSU is damaged.
Remedy: Call agent: • Restart the printer. Service engineer: 1. Check that DS7 Printmech LED is turned on. If it is not the case, replace the Printmech PCA. 2. If the problem persist, replace the PSU.
Code: 12.3:10
Description: Printmech 12V_BULLI_2 to Vapor Removal PCA out of range
Causes: The 12V cable from Printmech to Vapor Removal PCA has a problem Printmech PCA is damaged.
Remedy: Call agent: • Restart the printer. Service engineer: 1. Check cable Printmech to Vapor Removal PCA . 2. Check the Printmech PCA.
Code: 12.4:10
Description: Printmech 24V_BULLI_1 to Vapor Removal PCA out of range
Causes: The 24V cable from Printmech to Vapor Removal PCA has a problem Printmech PCA is damaged.
Remedy: Call agent: • Restart the printer. Service engineer: 1. Check the Printmech cable to Vapor Removal PCA. 2. Check the Printmech PCA.
Code: 12.5:10
Description: Printmech: 12V to ISS, DD, 42Vdc motor drivers, Top cover fans and PZ fans failure
Causes: The 12V cable from Printmech to ISS, Interconnect and PZ fans has a problem Printmech PCA is damaged.
Remedy: Call agent: • Restart the printer. Service engineer: 1. Check the Printmech cables to the ISS, Interconnect and PZ fans. 2. Check the Printmech PCA.
Code: 12.6:10
Description: Printmech: 42V to Carriage PCA failure
Causes: The 42V cable from Printmech to Carriage PCA has a problem Printmech PCA is damaged
Remedy: Call agent: • Restart the printer. Service engineer: 1. Check the Printmech cable to Carriage PCA. 2. Check the Printmech PCA.
Code: 12.7:10
Description: Printmech: Hannibal1 24V failure. Check APS relief valve, SVS motor and Rack engage motor
Causes: The 24V cable from Printmech to Interconnect has a problem Printmech PCA is damaged.
Remedy: Call agent: • Restart the printer. Service engineer: 1. Check the APS relief valve, SVS motor and Rack engage motor. 2. Check the Printmech PCA.
Code: 12.8:10
Description: Printmech: Hannibal2 24V failure. Check Spit-on roller motor and Primer motor
Causes: The 24V cable from Printmech to Interconnect has a problem Printmech PCA is damaged.
Remedy: Call agent: • Restart the printer. Service engineer: 1. Check the Spit-on roller motor and Primer motor. 2. Check the Printmech PCA.