Description: Fusing warm-up trouble (Middle of the heating roller). Detected temperature of the thermistor/1 (TH1) or thermistor/2 (TH2) does not go up a given range of temperature even after a lapse of given period of time at warm up.
Causes: • Fusing unit • Thermistor/1 (TH1) • Thermistor/2 (TH2) • DC power supply (DCPU) • MFP board (MFPB)
Remedy: 1. Check the fusing unit for correct installation (whether it is secured in position). 2. Check the open/close operation of the right door. 3. Check the connector between the fusing unit-relay CN19-MFPB CN18E for proper connection and correct as necessary. 4. Check the connector between the fusing unit-relay CN7AC-DCPU CN2 for proper connection and correct as necessary. 5. Check the connector between MFPB CN2E-DCPU CN7 for proper connection and correct as necessary. 6. Replace the fusing unit. 7. Replace MFPB. 8. Replace DCPU.
Description: Fusing abnormally high temperature detection (Middle of the heating roller). Detected temperature of the thermistor/1 (TH1) goes beyond a given temperature for a given period of time consecutively.
Remedy: 1. Check the fusing unit for correct installation (whether it is secured in position). 2. Check the open/close operation of the right door. 3. Check the connector between the fusing unit-relay CN19-MFPB CN18E for proper connection and correct as necessary. 4. Replace the fusing unit. 5. Replace MFPB.
Description: Fusing abnormally high temperature detection (Edge of the heating roller). Detected temperature of the thermistor/2 (TH2) goes beyond a given temperature for a given period of time consecutively.
Remedy: 1. Check the fusing unit for correct installation (whether it is secured in position). 2. Check the open/close operation of the right door. 3. Check the connector between the fusing unit-relay CN19-MFPB CN18E for proper connection and correct as necessary. 4. Replace the fusing unit. 5. Replace MFPB.
Description: Fusing abnormally high temperature detection (Hard protector). The hard protector signal error is detected for a given period of time consecutively.
Remedy: 1. Check the fusing unit for correct installation (whether it is secured in position). 2. Check the open/close operation of the right door. 3. Check the connector between the fusing unit-relay CN19-MFPB CN18E for proper connection and correct as necessary. 4. Replace the fusing unit. 5. MFPB F3E conduction check 6. Replace MFPB.
Description: Fusing abnormally low temperature detection (Middle of the heating roller). Detected temperature of the thermistor/1 (TH1) goes below a given temperature for a given period of time consecutively after warm up is completed.
Remedy: 1. Check the fusing unit for correct installation (whether it is secured in position). 2. Check the open/close operation of the right door. 3. Check the connector between the fusing unit-relay CN19-MFPB CN18E for proper connection and correct as necessary. 4. Replace the fusing unit. 5. Replace MFPB.
Description: Fusing abnormally low temperature detection (Edge of the heating roller) Detected temperature of the thermistor/2 (TH2) goes below a given temperature for a given period of time consecutively after warm up is completed.
Remedy: 1. Check the fusing unit for correct installation (whether it is secured in position). 2. Check the open/close operation of the right door. 3. Check the connector between the fusing unit-relay CN19-MFPB CN18E for proper connection and correct as necessary. 4. Replace the fusing unit. 5. Replace MFPB.
Description: Fusing sensor wire breaks detection (Middle of the heating roller) The maximum value and minimum value of detected temperature of the thermistor/2 (TH2) is compared after a lapse of given time from starting of warm up and the gap between the value of maximum and minimum is below a given temperature.
Remedy: 1. Check the fusing unit for correct installation (whether it is secured in position). 2. Check the open/close operation of the right door. 3. Check the connector between the fusing unit-relay CN19-MFPB CN18E for proper connection and correct as necessary. 4. Replace the fusing unit. 5. Replace MFPB.
Description: Fusing sensor wire breaks detection (Edge of the heating roller) The maximum value and minimum value of detected temperature of the thermistor/2 (TH2) is compared after a lapse of given time from starting of warm up and the gap between the value of maximum and minimum is below a given temperature.
Remedy: 1. Check the fusing unit for correct installation (whether it is secured in position). 2. Check the open/close operation of the right door. 3. Check the connector between the fusing unit-relay CN19-MFPB CN18E for proper connection and correct as necessary. 4. Replace the fusing unit. 5. Replace MFPB.
Nhận ưu đãi sớm nhất khi chương trình diễn ra
Đăng ký nhận bản tin
Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này.
Chính sách cookie
Những cookie này là cần thiết để trang web hoạt động đúng cách.
Những cookie này giúp chúng tôi hiểu cách khách truy cập tương tác với trang web.
Những cookie này được sử dụng để cung cấp quảng cáo cá nhân hóa.