Description: Image process communication abnormality
- Communication abnormality between the engine control of the overall control board (OACB) and that of the printer control board (PRCB) While in the stand-by, a process Ready signal cannot be detected for a specified period of time.
Causes: Overall control board (OACB) Printer control board (PRCB)
Code: C-2201
Description: Developing motor (M3) speed abnormality.
- While M3 is ON, an EM error signal has been detected 5 times in succession within a specified period of time.
Causes: Developing motor (M3) Printer control board (PRCB)
Code: C-2202
Description: Drum motor (M1) speed abnormality.
- While M1 is ON, an EM error signal has been detected 5 times in succession within a specified period of time.
Causes: Drum motor (M1) Printer control board (PRCB)
Code: C-2301
Description: Drum cooling fan (FM4) abnormality.
- While FM4 is ON, an EM error signal has been detected 5 times in succession within a specified period of time.
Causes: Drum cooling fan (FM4) Printer control board (PRCB)
Code: C-2302
Description: Developing suction fan motor (FM6) abnormality.
- While FM6 is ON, an EM error signal has been detected 5 times in succession within a specified period of time.
Causes: Developing suction fan motor (FM6) Printer control board (PRCB)
Code: C-2303
Description: Developing cooling fan (FM7) abnormality.
- While FM7 is ON, an EM error signal has been detected 5 times in succession within a specified period of time.
Causes: Developing cooling fan (FM7) Printer control board (PRCB)
Code: C-2401
Description: High machine inside temperature abnormality.
- When the temperature around the drum is above 58 °C
Causes: TCR sensor (TCRS) Printer control board (PRCB)
Code: C-2402
Description: Erase lamp (EL) connector slip-off abnormality.
- When EL turns ON before starting an initial charging, EL abnormality has been detected 15 times in succession at prescribed intervals after a specified period of time.
Causes: Erase lamp (EL) Printer control board (PRCB)