Các lỗi thường gặp

Code :
  • Code: C-3904
  • Description: Thermistor /2 (TH2) open abnormality (sub CPU detection)
    - In the sub CPU, the TH2 detection temperature detects a temperature between -8 and 20 °C for more than a specified period of time.
  • Causes: Thermistor /2 (TH2) Printer control board (PRCB)
  • Code: C-4001
  • Description: Index board (INDEXB) contact abnormality.
  • Causes: Index board (INDEXB) Overall control board (OACB)
  • Code: C-4101
  • Description: Polygon motor (M5) speed abnormality.
    - When M5 is ON, an error signal is detected 3 times in succession within a specified period of time.
  • Causes: Polygon motor (M5) Printer control board (PRCB)
  • Code: C-4401
  • Description: Laser drive board (LDB) abnormality.
    - When an overcurrent flows for laser output.
  • Causes: Laser drive board (LDB) Overall control board (OACB)
  • Code: C-4701
  • Description: Laser index abnormality.
    - When the cycle of the index is different from an expected value.
  • Causes: Index board (INDEXB) Overall control board (OACB)
  • Code: C-5001
  • Description: Main body control board communication abnormality 1
    - Communication abnormality between the overall control board (OACB) and the scanner drive board (SDB).
  • Causes: Overall control board (OACB) Scanner drive board (SDB)
  • Code: C-5002
  • Description: Main body control board communication abnormality 2
    - Communication abnormality, incoming command abnormality, platen operation sequence abnormality to the sub CPU in the overall control board (OACB).
  • Causes: Printer control board (PRCB)
  • Code: C-5003
  • Description: Sub CPU A/D conversion abnormality.
    - There is no response 2 times in succession to the A/D conversion request of the overall control board (OACB).
  • Causes: Printer control board (PRCB)