Description: Thermistor /2 (TH2) open abnormality (sub CPU detection)
- In the sub CPU, the TH2 detection temperature detects a temperature between -8 and 20 °C for more than a specified period of time.
Causes: Thermistor /2 (TH2) Printer control board (PRCB)
Code: C-4001
Description: Index board (INDEXB) contact abnormality.
Causes: Index board (INDEXB) Overall control board (OACB)
Code: C-4101
Description: Polygon motor (M5) speed abnormality.
- When M5 is ON, an error signal is detected 3 times in succession within a specified period of time.
Causes: Polygon motor (M5) Printer control board (PRCB)
Code: C-4401
Description: Laser drive board (LDB) abnormality.
- When an overcurrent flows for laser output.
Causes: Laser drive board (LDB) Overall control board (OACB)
Code: C-4701
Description: Laser index abnormality.
- When the cycle of the index is different from an expected value.
Causes: Index board (INDEXB) Overall control board (OACB)
Code: C-5001
Description: Main body control board communication abnormality 1
- Communication abnormality between the overall control board (OACB) and the scanner drive board (SDB).
Causes: Overall control board (OACB) Scanner drive board (SDB)
Code: C-5002
Description: Main body control board communication abnormality 2
- Communication abnormality, incoming command abnormality, platen operation sequence abnormality to the sub CPU in the overall control board (OACB).
Causes: Printer control board (PRCB)
Code: C-5003
Description: Sub CPU A/D conversion abnormality.
- There is no response 2 times in succession to the A/D conversion request of the overall control board (OACB).