Description: Toner bottle phase detection abnormality.
- While in the power switch (SW2) ON, the toner bottle position sensor (PS28) does not turn ON within a specified period of time after the toner bottle motor (M10) turns ON.
Causes: Toner bottle motor (M10) Toner bottle position sensor (PS28) Printer control board (PRCB)
Code: C-2701
Description: Charging abnormality.
- An error signal is detected 5 times in succession at prescribed intervals.
Causes: Charging corona High voltage unit (HV) Printer control board (PRCB)(FS
Code: C-2702
Description: Transfer lightning abnormality.
- There occurs a phenomenon 5 times in a job, in which an error signal is detected 3 times in succession at prescribed intervals.
Causes: Transfer/separation charger High voltage unit (HV) Printer control board (PRCB)
Code: C-2703
Description: Separation lightning abnormality.
- There occurs a phenomenon 5 times in a job, in which an error signal is detected 5 times in succession at prescribed intervals.
Causes: Transfer/separation charger High voltage unit (HV) Printer control board (PRCB)
Code: C-2801
Description: TCR output abnormality.
- When the TCR output is in excess of 3.0 V.
Causes: TCR sensor (TCRS) Printer control board (PRCB)
Code: C-2802
Description: TCR output abnormality.
- When the TCR sensor (TCRS) maximum output is 1.0 V or less.
Causes: TCR sensor (TCRS) Printer control board (PRCB)
Code: C-2803
Description: TCR output abnormality.
- When the output ripple voltage of the TCR sensor (TCRS) is less than 0.5 V.
Causes: TCR sensor (TCRS) Printer control board (PRCB)
Code: C-2804
Description: Toner density abnormality.
- When the L detection output is in excess of 2.6 V before the toner remaining sensor (PZS) detects a no toner condition, toner density does not recover even when toner is automatically supplied.