Description: Communication abnormality
- Communication abnormality between the engine control of the overall control board (OACB) and that of the printer control board (PRCB). While in the stand-by, an FS Ready signal cannot be detected for a specified period of time.
Causes: Overall control board (OACB) Printer control board (PRCB)
Description: FS
- FS communication abnormality. A serial communication is unavailable between the FS control board (FSCB) and the printer control board (PRCB).
Causes: FS control board (FSCB) Printer control board (PRCB)
Description: FS-511 Shift motor (M8) drive abnormality.
- When starting the home position movement, the shift home sensor (PS10) does not turn ON a specified period of time after M8 turns ON.
- When starting the shift position movement, PS10 does not turn OFF a specified period of time after M8 turns ON.
Causes: Shift motor (M8) Shift home sensor (PS10) FS control board (FSCB)
Description: FS-511:Tray lift motor (M7) drive abnormality.
- While in the main tray up drive, the main tray upper limit sensor (PS19) does not turn ON within a specified period of time after M7 turns ON.
- While in the main tray down drive, the lock signal of M7 is detected.
- While in the M7 ON, the main tray upper limit switch (SW2) or the main tray lower limit switch (SW3) turns ON.
Causes: Tray lift motor (M7) Main tray upper limit sensor (PS19) FS control board (FSCB)
Description: FS-511: Alignment motor (M5) drive abnormality.
- While in the alignment home position search, the alignment home sensor (PS9) does not turn ON within a specified period of time after M5 turns ON.
- While in the alignment operation, PS9 does not turn OFF within a specified period of time after M5 turns ON.
Causes: Alignment motor (M5) Alignment home sensor (PS9) FS control board (FSCB)
Description: FS-511: Paper exit roller release motor (M13) drive abnormality.
- When starting the pressure position drive, the exit roller home sensor (PS13) does not turn ON within a specified period of time after M13 turns ON.
- When starting the separation position drive, PS13 does not turn OFF within a specified period of time after M13 turns ON.
Causes: Paper exit roller release motor (M13) Exit roller home sensor (PS13) FS control board (FSCB)
Description: FS-511: Intermediate conveyance roller release motor (M12) drive abnormality.
- When starting the pressure position drive, the roller release home sensor (PS12) does not turn ON within a specified period of time after M12 turns ON.
- When starting the separation position drive, PS12 does not turn OFF within a specified period of time after M12 turns ON.
Causes: Intermediate conveyance roller release motor (M12) Roller release home sensor (PS12) FS control board (FSCB)
Nhận ưu đãi sớm nhất khi chương trình diễn ra
Đăng ký nhận bản tin
Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này.
Chính sách cookie
Những cookie này là cần thiết để trang web hoạt động đúng cách.
Những cookie này giúp chúng tôi hiểu cách khách truy cập tương tác với trang web.
Những cookie này được sử dụng để cung cấp quảng cáo cá nhân hóa.