Description: Printhead drive control out of range due to an external event beyond what the control is designed to handle.
Remedy: Step 1: Check the printhead unit cables JLSU1 and J6 for proper connection. Are they properly connected? Yes: Go to step 2. No: Reseat the cables.
Step 2: Inspect the printhead cables and connectors. Are they free of damage? Yes: Replace the controller board. No: Replace the printhead.
Code: 111.62
Description: Closed-loop printhead error, off-resonant PI effort state.
Remedy: Step 1: Check the printhead unit cables JLSU1 and J6 for proper connection. Are they properly connected? Yes: Go to step 2. No: Reseat the cables.
Step 2: Inspect the printhead cables and connectors. Are they free of damage? Yes: Replace the controller board. No: Replace the printhead.
Code: 111.63
Description: Timed out on POR sweep.
Remedy: Step 1: Check the printhead unit cables JLSU1 and J6 for proper connection. Are they properly connected? Yes: Go to step 2. No: Reseat the cables.
Step 2: Inspect the printhead cables and connectors. Are they free of damage? Yes: Replace the controller board. No: Replace the printhead.
Code: 111.64
Description: Attempted to exceed open loop drive limits.
Remedy: Step 1: Check the printhead unit cables JLSU1 and J6 for proper connection. Are they properly connected? Yes: Go to step 2. No: Reseat the cables.
Step 2: Inspect the printhead cables and connectors. Are they free of damage? Yes: Replace the controller board. No: Replace the printhead.
Code: 111.65
Description: Attempted to exceed open loop drive limits.
Remedy:
Code: 111.66
Description: Failed alignment of printhead.
Remedy: Step 1: Check the printhead unit cables JLSU1 and J6 for proper connection. Are they properly connected? Yes: Go to step 2. No: Reseat the cables.
Step 2: Inspect the printhead cables and connectors. Are they free of damage? Yes: Replace the controller board. No: Replace the printhead.
Code: 111.67
Description: Failed alignment of printhead.
Remedy: Step 1: Check the printhead unit cables JLSU1 and J6 for proper connection. Are they properly connected? Yes: Go to step 2. No: Reseat the cables.
Step 2: Inspect the printhead cables and connectors. Are they free of damage? Yes: Replace the controller board. No: Replace the printhead.
Code: 111.68
Description: Too many fake HSYNCs while aligning printhead.
Remedy: Step 1: Check the printhead unit cables JLSU1 and J6 for proper connection. Are they properly connected? Yes: Go to step 2. No: Reseat the cables.
Step 2: Inspect the printhead cables and connectors. Are they free of damage? Yes: Replace the controller board. No: Replace the printhead.