Remedy: Step 1: Check the printhead unit cables JLSU1 and J6 for proper connection. Are they properly connected? Yes: Go to step 2. No: Reseat the cables.
Step 2: Inspect the printhead cables and connectors. Are they free of damage? Yes: Replace the controller board. No: Replace the printhead.
Code: 111.54
Description: Closed-loop printhead error, amp Kp failed to converge.
Remedy: Step 1: Check the printhead unit cables JLSU1 and J6 for proper connection. Are they properly connected? Yes: Go to step 2. No: Reseat the cables.
Step 2: Inspect the printhead cables and connectors. Are they free of damage? Yes: Replace the controller board. No: Replace the printhead.
Code: 111.55
Description: Closed-loop printhead error while waiting for amp Kp to converge.
Remedy: Step 1: Check the printhead unit cables JLSU1 and J6 for proper connection. Are they properly connected? Yes: Go to step 2. No: Reseat the cables.
Step 2: Inspect the printhead cables and connectors. Are they free of damage? Yes: Replace the controller board. No: Replace the printhead.
Code: 111.56
Description: Closed-loop printhead error, amp Ki failed to converge.
Remedy: Step 1: Check the printhead unit cables JLSU1 and J6 for proper connection. Are they properly connected? Yes: Go to step 2. No: Reseat the cables.
Step 2: Inspect the printhead cables and connectors. Are they free of damage? Yes: Replace the controller board. No: Replace the printhead.
Code: 111.57
Description: Closed-loop printhead error while waiting for amp Ki to converge.
Remedy: Step 1: Check the printhead unit cables JLSU1 and J6 for proper connection. Are they properly connected? Yes: Go to step 2. No: Reseat the cables.
Step 2: Inspect the printhead cables and connectors. Are they free of damage? Yes: Replace the controller board. No: Replace the printhead.
Remedy: Step 1: Check the printhead unit cables JLSU1 and J6 for proper connection. Are they properly connected? Yes: Go to step 2. No: Reseat the cables.
Step 2: Inspect the printhead cables and connectors. Are they free of damage? Yes: Replace the controller board. No: Replace the printhead.
Code: 111.59
Description: Closed-loop printhead error, forward and reverse capture times differ by too much.
Remedy: Step 1: Check the printhead unit cables JLSU1 and J6 for proper connection. Are they properly connected? Yes: Go to step 2. No: Reseat the cables.
Step 2: Inspect the printhead cables and connectors. Are they free of damage? Yes: Replace the controller board. No: Replace the printhead.
Remedy: Step 1: Check the printhead unit cables JLSU1 and J6 for proper connection. Are they properly connected? Yes: Go to step 2. No: Reseat the cables.
Step 2: Inspect the printhead cables and connectors. Are they free of damage? Yes: Replace the controller board. No: Replace the printhead.