Description: The adjustment data evacuated by resolutions is not available.
Causes: Overall control board (OACB)
Description: A density conversion gamma curve cannot be created normally.
Causes: Overall control board (OACB)
Description: Despite of the MPC not being terminated, the initial sampling of the APC is attempted.
Causes: Overall control board (OACB) Image controller firmware
Description: While executing the APC, the execution of the MPC is attempted.
Causes: Overall control board (OACB) Image controller firmware
Description: Sequentially shot page area abnormality. Due to an image area abnormality on the memory, images cannot be developed on the memory.
Causes: Overall control board (OACB) Image controller firmware
Description: The scan operation starts before the original skew adjustment is terminated. (The skew adjustment is too late.)
Causes: Printer control board (PRCB) Original conveyance sensor (PS306) Original skew sensor (PS307)
Description: The print operation starts before the paper mis-centering adjustment is terminated. (The mis-centering adjustment is too late.)
Causes: Centering sensor (PS66)
Description: The AGC is retried due to the decreased light volume of the exposure lamp. However, no error occurs.
Causes: Exposure lamp (L1)