Mã lỗi Konica-Minolta bizhub 601 — Trang 18/20

Code: C-D020

Description: Hard disk verification error. After removal of temporary data from hard disk, error was detected during verification.
Causes: Overall control board (OACB) Image controller firmware Hard disk /1 (HD-510)

Code: C-D101

Description: Tandem communication error.
Causes: Overall control board (OACB)

Code: C-D102

Description: Tandem image communication error.
Causes: Overall control board (OACB)

Code: C-D201

Description: Overall control board (OACB) detects the CPU cooling fan (FM22) locked.
Causes: Overall control board (OACB) CPU cooling fan (FM22)

Code: C-D202

Description: Overall control board (OACB) detects the HDD cooling fan (FM24) locked.
Causes: Overall control board (OACB) HDD cooling fan (FM24)

Code: C-D204

Description: The lock of the overall control board cooling fan (FM23) is detected on the overall control board (OACB).
Causes: Overall control board (OACB) Overall control board cooling fan (FM23)

Code: C-D301

Description: The CF card checksum is abnormal.
Causes: Overall control board (OACB) CF card (CF)

Code: C-D302

Description: The management of CF card is deleted.
Causes: Overall control board (OACB) CF card (CF)