Description: The communication between the overall control board (OACB) and the operation board /1 (PWB1) does not start after the power switch (SW2) turns ON.
Causes: Overall control board (OACB) Operation board /1 (PWB1)
Description: The conveyance roller pressure/ release home sensor (PS308) does not turns OFF within a specified period of time after the conveyance roller pressure/ release motor (M4) starts its operation.
Causes: Scanner drive board (SDB) Conveyance roller pressure/ release motor (M4) Conveyance roller pressure/ release home sensor (PS308)
Description: The EM signal of the cooling fan (FM1) shows an abnormal condition when a specified period of time elapses after FM1 turns ON. This abnormal condition recurs when a specified period of time elapses after FM1 is turned OFF and then ON again.
Causes: Scanner drive board (SDB) Cooling fan (FM1)