Code :
  • Code: C1115
  • Description: Center fold knife motor’s malfunction Detection timing <When FS-534+SD-511 is installed> The center fold knife home sensor (PS8) is not blocked or unblocked even after the set period of time has elapsed after the center fold knife motor (M9) is turned ON. <When FS-535+SD-512 is installed> The center fold home sensor (PS8) is not blocked even after the set period of time has elapsed while the center fold knife motor (M9) is energized.
  • Causes: <When FS-534+SD-511 is installed> • Center fold knife motor (M9) • Center fold knife home sensor (PS8) • SD drive board (SDDB) • FS control board (FSCB) <When FS-535+SD-512 is installed> • Center fold knife motor (M9) • Center fold home sensor (PS8) • SD drive board (SDDB) • FS control board (FSCB)
  • Remedy: When FS-534+SD-511 is installed: 1 Check the connector between M9-SDDB J11 for proper connection, and correct as necessary. 2 Check the connector of M9 for proper drive coupling, and correct as necessary. 3 Check the connector between PS8-relay CN10-SDDB J7 for proper connection, and correct as necessary. 4 PS8 I/O check, sensor check SDDB J7-3 (ON) SD-511 6-G 5 M9 operation check SDDB J11-11 to 20 SD-511 1 to 2-B 6 Replace M9 7 Replace SDDB 8 Replace FSCB. When FS-535+SD-512 is installed: 1 Check the connector between M9-SDDB J11 for proper connection, and correct as necessary. 2 Check the connector of M9 for proper drive coupling, and correct as necessary. 3 Check the connector between PS8-relay CN10-SDDB J7 for proper connection, and correct as necessary. 4 PS8 I/O check, sensor check SDDB J7-3 (ON) SD-512 5-G 5 M9 operation check SDDB CN11-11 to 20 SD-512 1-B 6 Replace M9 7 Replace SDDB 8 Replace FSCB
  • Code: C1124
  • Description: Sheet feeder up/down drive failure (lower) <When FS-535+PI-505 is installed> The tray upper limit sensor /Lw (PS209) or tray lower limit sensor /Lw (PS210) are not turned ON even after the set period of time has elapsed after the tray lift motor /Lw (M202) is energized.
  • Causes: • Tray lift motor /Lw (M202) • Tray upper limit sensor /Lw (PS209) • Tray lower limit sensor /Lw (PS210) • PI drive board (PIDB) • FS control board (FSCB)
  • Remedy: 1 Check the connector between M202-relay CN206- PIDB CN56 for proper connection, and correct as necessary. 2 Check the connector of M202 for proper drive coupling, and correct as necessary. 3 Check the connector between PS209-relay CN237- PIDB CN53<A> for proper connection, and correct as necessary. 4 Check the connector between PS210-relay CN236- PIDB CN53<A> for proper connection, and correct as necessary. 5 PS209 I/O check, sensor check PIDB CN53<A>-8 (ON) PI-505 8-C to D 6 PS210 I/O check, sensor check PIDB CN53<A>-11 (ON) PI-505 9-C to D 7 M202 operation check PIDB CN56-5 to 6 PI-505 7-C to D 8 Replace M202 9 PIDB ICP2 conduction check 10 Replace PIDB 11 Replace FSCB
  • Code: C1125
  • Description: Sheet feeder up/down drive failure (upper) <When FS-535+PI-505 is installed> The tray lower limit sensor /Up (PS205) or tray upper limit sensor /Up (PS204) are not turned ON even after the set period of time has elapsed after the tray lift motor /Up (M201) is energized.
  • Causes: • Tray lift motor /Up (M201) • Tray upper limit sensor /Up (PS204) • Tray lower limit sensor /Up (PS205) • PI drive board (PIDB) • FS control board (FSCB)
  • Remedy: 1 Check the connector between M201-relay CN203- PIDB CN54 for proper connection, and correct as necessary. 2 Check the connector of M201 for proper drive coupling, and correct as necessary. 3 Check the connector between PS204-relay CN235- PIDB CN55 for proper connection, and correct as necessary. 4 Check the connector between PS205-relay CN235- PIDB CN55 for proper connection, and correct as necessary. 5 PS204 I/O check, sensor check PIDB CN55-8 (ON) PI-505 5-C to D 6 PS205 I/O check, sensor check PIDB CN55-7 (ON) PI-505 6-C to D 7 M201 operation check PIDB CN54-7 to 8 PI-505 4-C to D 8 Replace M201 9 PIDB ICP2 conduction check 10 Replace PIDB 11 Replace FSCB
  • Code: C1127
  • Description: Punch oscillating motor’s drive malfunction <When FS-535+PK-521 is installed> The PK punch home sensor (PS303) is not turned ON even after the set period of time has elapsed while the punch oscillating motor (M302) is energized.
  • Causes: • Punch oscillating motor (M302) • PK punch home sensor (PS303) • Punch control board (PKCB) • FS control board (FSCB)
  • Remedy: 1 Check the connector between M302-relay CN342- relay CN341-PKCB CN37 for proper connection, and correct as necessary. 2 Check the connector of M302 for proper drive coupling, and correct as necessary. 3 Check the connector between PS303-relay CN342- relay CN341-PKCB CN34 for proper connection, and correct as necessary. 4 PS303 I/O check, sensor check PKCB CN37-2 (ON) PK-521 5-C 5 M302 operation check PKCB CN34-1 to 6 PK-521 5-C 6 Replace M302 7 Replace PKCB 8 Replace FSCB
  • Code: C1130
  • Description: 1st stopper motor's drive malfunction Detection timing <When FS-535+ZU-606 is installed> The 1st folding stopper home sensor (PS603) is not turned ON even after the set period of time has elapsed after the 1st stopper motor (M602) starts searching home position.
  • Causes: • 1st stopper motor (M602) • 1st folding stopper home sensor (PS603) • ZU control board (ZUCB)
  • Remedy: 1 Check the connector between M602-relay CN30- ZUCB CN15 for proper connection, and correct as necessary. 2 Check the connector of M602 for proper drive coupling, and correct as necessary. 3 Check the connector between PS603-relay CN636- ZUCB CN4 for proper connection, and correct as necessary. 4 PS603 I/O check, sensor check ZUCB CN4-11 (ON) ZU-606 5-C 5 M602 operation check ZUCB CN15-4 to 6 ZU-606 3-C 6 Replace M602 7 ZUCB ICP7 conduction check 8 Replace ZUCB
  • Code: C1131
  • Description: 2nd stopper motor’s drive malfunction Detection timing <When FS-535+ZU-606 is installed> The 2nd stopper home sensor (PS604) is not turned ON even after the set period of time has elapsed after the 2nd stopper motor (M603) starts searching home position.
  • Causes: • 2nd folding stopper motor (M603) • 2nd folding stopper home sensor (PS604) • ZU control board (ZUCB)
  • Remedy: 1 Check the connector between M603-relay CN675- relay CN30-ZUCB CN15 for proper connection, and correct as necessary. 2 Check the connector of M603 for proper drive coupling, and correct as necessary. 3 Check the connectors between PS604-relay CN674- relay CN636-ZUCB CN4 for proper connection, and correct as necessary. 4 PS604 I/O check, sensor check ZUCB CN4-5 (ON) ZU-606 4 to 5-C 5 M603 operation check ZUCB CN15-7 to 12 ZU-606 4-C 6 Replace M603 7 ZUCB ICP6 conduction check 8 Replace ZUCB
  • Code: C1132
  • Description: Punch drive motor’s malfunction Detection timing <When FS-534+PK-520 is installed> The punch home sensor (PS1) is not blocked or unblocked even after the set period of time has elapsed while the punch drive motor (M1) is energized. <When FS-535+PK-521 is installed> The PK punch home sensor/2 (PS301) is not blocked or unblocked even after the set period of time has elapsed while the punch drive motor (M301) is energized.
  • Causes: <When FS-534+PK-520 is installed> • Punch drive motor (M1) • Punch home sensor (PS1) • FS control board (FSCB) <When FS-535+PK-521 is installed> • Punch drive motor (M301) • PK punch home sensor/2 (PS301) • Punch control board (PKCB) • FS control board (FSCB)
  • Remedy: When FS-534+PK-520 is installed: 1 Check the connector between M1-relay CN351-FSCB J7 for proper connection, and correct as necessary. 2 Check the connector of M1 for proper drive coupling, and correct as necessary. 3 Check the connector between PS1-FSCB J7 for proper connection, and correct as necessary. 4 PS1 I/O check, sensor check FSCB J7-5 (ON) FS-534 (PK-520) 7-K 5 M1 operation check FSCB J7-7 to 8 FS-534 (PK-520) 7-K 6 Replace M1 7 Replace FSCB. When FS-535+PK-521 is installed: 1 Check the connector between M301-relay CN351- PKCB CN35 for proper connection, and correct as necessary. 2 Check the connector of M301 for proper drive coupling, and correct as necessary. 3 Check the connector between PS301-PKCB CN36 for proper connection, and correct as necessary. 4 PS301 I/O check, sensor check PKCB CN36-5 (ON) PK-521 3-C 5 M301 operation check PKCB CN35-1 to 3 PK-521 2-C 6 Replace M301 7 Replace PKCB 8 Replace FSCB
  • Code: C1133
  • Description: Punch shift motor’s drive malfunction Detection timing <When FS-535+ZU-606 is installed> The punch shift home sensor (PS605) is not turned ON, or is not turned OFF after it is turned ON, even after the set period of time has elapsed after the punch shift motor (M605) starts searching its home position.
  • Causes: • Punch shift motor (M605) • Punch shift home sensor (PS605) • ZU control board (ZUCB)
  • Remedy: 1 Check the connector between M605-ZUCB CN5 for proper connection, and correct as necessary. 2 Check the connector of M605 for proper drive coupling, and correct as necessary. 3 Check the connector between PS605-ZUCB CN3 for proper connection, and correct as necessary. 4 PS605 I/O check, sensor check ZUCB CN3-2 (ON) ZU-606 6-C 5 M605 operation check ZUCB CN5-1 to 6 ZU-606 2-C 6 Replace M605 7 ZUCB ICP5 conduction check 8 Replace ZUCB