Description: Thermistor /4 (TH4) low abnormality detection (hardware). The output voltage of the TH4 is detected as a low temperature (- 6°C or lower) or high temperature (240.5°Cor higher) abnormality in the comparator circuit.
Description: The rotation of the scanner cooling fan (FM7) is checked, and 24V power source is also checked. An abnormal condition occurs with the FM7 EM signal a specified period of time after FM7 turns ON. This abnormal condition recurs even a specified period of time after FM7 is turned OFF and then turned ON, and an error detection signal (24V cut off) is detected.
Causes: Scanner drive board (SDB) Scanner cooling fan (FM7) DC power supply /2 (DCPS2) Wiring harness earth fault Loose connection
Description: The rotation of the write unit cooling fan /1 (FM5) is checked, and 24V power source is also checked. An abnormal condition occurs with the FM5 EM signal a specified period of time after FM5, the write unit cooling fan /2 (FM8) turns ON. This abnormal condition recurs even a specified period of time after FM5/FM8 is turned OFF and then turned ON, and an error detection signal (24V cut off) is detected.
Causes: Write unit cooling fan /1 (FM5) Overall control board (OACB) DC power supply /2 (DCPS2) AC drive board (ACDB) Wiring harness earth fault
Description: The blowout of ICP for the write unit cooling fan /1 (FM5) in the AC drive board (ACDB) is checked. An abnormal condition occurs with the FM5 EM signal a specified period of time after FM5, the write unit cooling fan /2 (FM8) turns ON. This abnormal condition recurs even a specified period of time after FM5/FM8 is turned OFF and then turned ON, and an error detection signal (blowout of ICP) is detected.
Causes: Write unit cooling fan /1 (FM5) Overall control board (OACB) DC power supply /2 (DCPS2) AC drive board (ACDB) Wiring harness earth fault
Description: The rotation of the write unit cooling fan /1 (FM5) is checked. An abnormal condition occurs with the FM5 EM signal a specified period of time after FM5 and write unit cooling fan /2 (FM8) turns ON. This abnormal condition recurs even a specified period of time after FM5/FM8 is turned OFF and then turned ON, and an error detection signal (24V cut off/blowout of ICP) is not detected.
Causes: Write unit cooling fan /1 (FM5) Write unit cooling fan /2 (FM8) AC drive board (ACDB) Wiring harness earth fault Loose connection