Description: The rotation of the developing cooling fan (FM19) is checked. An abnormal condition occurs with the FM19 EM signal a specified period of time after FM19 is turned ON. This abnormal condition recurs even a specified period of time after FM19 is turned OFF and then ON again, and an error detection signal (24V cut off/blowout of ICP) is not detected.
Causes: Confirmation of the wiring harness and the connector DC power supply /2 (DCPS2) Printer control board (PRCB)
Description: Rotation of paper exit cooling fan /Lw1 (FM13), /Lw2 (FM14) is checked. An abnormal condition occurs with the FM13, FM14 EM signal a specified period of time after FM13, FM 14 is turned ON. This abnormal condition is detected even a specified period of time after FM13, FM14 is turned OFF and then ON again.
Causes: Confirmation of the wiring harness and the connector Paper exit cooling fan /Lw1 (FM13) Paper exit cooling fan /Lw2 (FM14) Printer control board (PRCB)
Description: Rotation of paper exit cooling fan /Up1 (FM15), /Up2 (FM17) is checked. An abnormal condition occurs with the FM15, FM17 EM signal a specified period of time after FM15, FM 17 is turned ON. This abnormal condition is detected even a specified period of time after FM15, FM17 is turned OFF and then ON again.
Causes: Confirmation of the wiring harness and the connector Paper exit cooling fan /Up1 (FM15) Paper exit cooling fan /Up2 (FM17) Printer control board (PRCB)
Description: The blowout of a 12V ICP for the AC drive board (ACDB) is checked. In the serial initial communication, a signal of the blowout of a 12V ICP (AC drive) is detected.
Causes: Confirmation of the wiring harness and the connector AC drive board (ACDB)
Description: The blowout of a 5V ICP for the AC drive board (ACDB) is checked. In the serial initial communication, a signal of the blowout of a 5V ICP (AC drive) is detected.
Causes: Confirmation of the wiring harness and the connector (ACDB) AC drive board (ACDB)
Description: 12V ICP blowout in the ADU drive board (ADUDB). A -5V ICP blowout signal and blowout of a 12V ICP signal are detected for the serial initial communication.
Causes: Confirmation of the wiring harness and the connector ADU drive board (ADUDB) DC power supply /2 (DCPS2)
Description: 24V power source of the ADU drive board is checked. At the start, an error detection signal (blowout of ICP for the transfer exposure lamp/solenoid) is detected, and an error detection signal (24V cut off) is detected.
Causes: Confirmation of the wiring harness and the connector Centering sensor (PS1) Transfer exposure lamp (EL2) ADU lock solenoid (SD1) Reverse/exit solenoid (SD2) Fusing solenoid (SD3) ADU drive board (ADUDB) DC power supply /2 (DCPS2)
Nhận ưu đãi sớm nhất khi chương trình diễn ra
Đăng ký nhận bản tin
Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này.
Chính sách cookie
Những cookie này là cần thiết để trang web hoạt động đúng cách.
Những cookie này giúp chúng tôi hiểu cách khách truy cập tương tác với trang web.
Những cookie này được sử dụng để cung cấp quảng cáo cá nhân hóa.