Description: Fusing heating roller high temperature abnormality (hardware). An abnormal condition is detected with the fusing error detection signal 4.
Causes: Confirmation of the wiring harness and the connector Fusing temperature sensor / 3 (TH3) Fusing heater lamp /3 (L3) Printer control board (PRCB) AC drive board (ACDB)
Description: Fusing roller /Up low temperature abnormality (software). TH1 does not get to 75°C when a specified period of time has elapsed after the main switch (SW1) is turned ON for the fusing ON control.
Causes: Confirmation of the wiring harness and the connector Fusing temperature sensor / 1 (TH1) Fusing heater lamp /1 (L1) Fusing heater lamp /2 (L2) Printer control board (PRCB) AC drive board (ACDB)
Description: Fusing heating roller low temperature abnormality (software). TH3 does not get to 50°C when a specified period of time has elapsed after the main switch (SW1) is turned ON for the fusing ON control.
Causes: Confirmation of the wiring harness and the connector Fusing temperature sensor / 3 (TH3) Fusing heater lamp /3 (L3) Printer control board (PRCB) AC drive board (ACDB)
Description: Fusing roller /Up sensor abnormality (software). TH1 detects a temperature of 230°C or above 30 times in a row in a specified period of time.
Causes: Confirmation of the wiring harness and the connector Fusing temperature sensor / 1 (TH1) Fusing heater lamp /1 (L1) Fusing heater lamp /2 (L2) Printer control board (PRCB) AC drive board (ACDB)
Description: Fusing heating roller sensor abnormality (software). TH3 detects a temperature of 220°C or above 30 times in a row in a specified period of time.
Causes: Confirmation of the wiring harness and the connector Fusing temperature sensor / 3 (TH3) Fusing heater lamp /3 (L3) Printer control board (PRCB) AC drive board (ACDB)
Description: Fusing roller /Up sensor abnormality (hardware). The output voltage of the TH1 is detected as a low temperature abnormality (- 6°C or lower) in the comparator circuit.
Causes: Confirmation of the wiring harness and the connector Fusing temperature sensor / 1 (TH1) Fusing heater lamp /1 (L1) Fusing heater lamp /2 (L2) Printer control board (PRCB) AC drive board (ACDB)
Description: Fusing heating roller sensor abnormality (hardware). The output voltage of the TH3 is detected as a low temperature abnormality (-6°C or lower) in the comparator circuit.
Causes: Confirmation of the wiring harness and the connector Fusing temperature sensor / 3 (TH3) Fusing heater lamp /3 (L3) Printer control board (PRCB) AC drive board (ACDB)
Description: Fusing roller /Up abnormality detection (hardware). The output voltage of the TH2 is detected as a low temperature (-6°C or lower) or high temperature (240.5°C or higher) abnormality in the comparator circuit.
Causes: Confirmation of the wiring harness and the connector Fusing temperature sensor / 2 (TH2) Fusing heater lamp /1 (L1) Fusing heater lamp /2 (L2) Printer control board (PRCB) AC drive board (ACDB)
Nhận ưu đãi sớm nhất khi chương trình diễn ra
Đăng ký nhận bản tin
Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này.
Chính sách cookie
Những cookie này là cần thiết để trang web hoạt động đúng cách.
Những cookie này giúp chúng tôi hiểu cách khách truy cập tương tác với trang web.
Những cookie này được sử dụng để cung cấp quảng cáo cá nhân hóa.