Description: Fusing heating roller abnormality detection (hardware). The output voltage of the TH4 is detected as a low temperature (-6°C or lower) or high temperature (240.5°C or higher) abnormality in the comparator circuit.
Causes: Confirmation of the wiring harness and the connector Fusing temperature sensor / 4 (TH4) Fusing heater lamp / 3 (L3) Printer control board (PRCB) AC drive board (ACDB)
Description: When the speed of the polygon motor (M17) is being switched, a speed lock signal is not detected within a specified period of time.
Causes: Confirmation of the wiring harness and the connector Write unit (Polygon motor drive board (PMDB) Polygon motor (M17) ) DC power supply /2 (DCPS2)
Description: The rotation of the write unit cooling fan /1 (FM5) is checked, and 24V power source is also checked. An abnormal condition occurs with the FM5 EM signal a specified period of time after FM5 turns ON. This abnormal condition recurs even a specified period of time after FM5 is turned OFF and then turned ON, and an error detection signal (24V cut off) is detected.
Causes: Confirmation of the wiring harness and the connector Write unit cooling fan /1 (FM5) AC drive board (ACDB) DC power supply /2 (DCPS2)
Description: The blowout of ICP for the write unit cooling fan /1 (FM5) in the AC drive board (ACDB) is checked. An abnormal condition occurs with the FM5 EM signal a specified period of time after FM5 turns ON. This abnormal condition recurs even a specified period of time after FM5 is turned OFF and then turned ON, and an error detection signal (blowout of ICP) is detected.
Causes: Confirmation of the wiring harness and the connector Write unit cooling fan /1 (FM5) AC drive board (ACDB) DC power supply /2 (DCPS2)
Description: The rotation of the write unit cooling fan /1 (FM5) is checked. An abnormal condition occurs with the FM5 EM signal a specified period of time after FM5 turns ON. This abnormal condition recurs even a specified period of time after FM5 is turned OFF and then turned ON, and an error detection signal (24V cut off/ blowout of ICP) is not detected.
Causes: Confirmation of the wiring harness and the connector Write unit cooling fan /1 (FM5) AC drive board (ACDB) DC power supply /2 (DCPS2)
Description: The rotation of the write unit cooling fan /2 (FM8) is checked and the 24V power source is also checked. An abnormal condition occurs with the FM8 EM signal a specified period of time after the write unit cooling fan /2 (FM8) turns ON. This abnormal condition recurs even a specified period of time after FM8 is turned OFF and then turned ON, and an error detection signal (24V cut off) is detected.
Causes: Confirmation of the wiring harness and the connector Write unit cooling fan /2 (FM8) AC drive board (ACDB) DC power supply /2 (DCPS2)
Description: The blowout of ICP for the write unit cooling fan /2 (FM8) in the AC drive board (ACDB) is checked. An abnormal condition occurs with the FM8 EM signal a specified period of time after the write unit cooling fan /2 (FM8) turns ON. This abnormal condition recurs even a specified period of time after FM8 is turned OFF and then turned ON, and an error detection signal (blowout of ICP) is detected.
Causes: Confirmation of the wiring harness and the connector Write unit cooling fan /2 (FM8) AC drive board (ACDB) DC power supply /2 (DCPS2)
Nhận ưu đãi sớm nhất khi chương trình diễn ra
Đăng ký nhận bản tin
Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này.
Chính sách cookie
Những cookie này là cần thiết để trang web hoạt động đúng cách.
Những cookie này giúp chúng tôi hiểu cách khách truy cập tương tác với trang web.
Những cookie này được sử dụng để cung cấp quảng cáo cá nhân hóa.