Description: EEPROM access error (TC C)
• An error was found when reading or writing data.
• The error was found when reading out the counter value.
Remedy: 1 Clean the connection between the toner cartridge and the machine if dirty. 2 Reinstall toner cartridge. 3 Check the harness for proper connection and correct as necessary. 4 Change toner cartridge. 5 Change PRCB.
Code: C2A02
Description: EEPROM access error (TC M)
• An error was found when reading or writing data.
• The error was found when reading out the counter value.
Remedy: 1 Clean the connection between the toner cartridge and the machine if dirty. 2 Reinstall toner cartridge. 3 Check the harness for proper connection and correct as necessary. 4 Change toner cartridge. 5 Change PRCB.
Code: C2A03
Description: EEPROM access error (TC Y)
• An error was found when reading or writing data.
• The error was found when reading out the counter value.
Remedy: 1 Clean the connection between the toner cartridge and the machine if dirty. 2 Reinstall toner cartridge. 3 Check the harness for proper connection and correct as necessary. 4 Change toner cartridge. 5 Change PRCB.
Code: C2A04
Description: EEPROM access error (TC K)
• An error was found when reading or writing data.
• The error was found when reading out the counter value.
Remedy: 1 Clean the connection between the toner cartridge and the machine if dirty. 2 Reinstall toner cartridge. 3 Check the harness for proper connection and correct as necessary. 4 Change toner cartridge. 5 Change PRCB.
Code: C3101
Description: Fusing roller separation failure
• With the fusing roller being retracted, the pulse of the fusing roller retraction sensor does not change even after the specified period of time has passed after the fusing retraction motor started rotating.
• With the fusing roller being pressed, the pulse of the roller retraction sensor does not change even after the specified period of time has passed after the fusing retraction motor started rotating.
• During a pressure operation of the fusing roller, the fusing roller is not at the pressed position even after the roller retraction sensor counts the specified number of pulses after the fusing retraction motor starts rotating.
Remedy: 1 Check the M12 connector for proper connection and correct as necessary. 2 PS38 I/O check, sensor check. 3 M12 operation check. 4 Change M12. 5 Change fusing unit. 6 Change PRCB.
Code: C3201
Description: Fusing motor failure to turn
• The motor lock signal remains HIGH for a predetermined continuous period of time while the motor remains stationary.
Remedy: 1 Check the M2 connector for proper connection and correct as necessary. 2 Check the loading status of the fusing unit drive, and correct the error as necessary. 3 Check the fusing unit, PRCB for proper connection and correct or change as necessary. 4 M2 operation check. 5 Change M2. 6 Change PRCB.
Code: C3202
Description: Fusing motor turning at abnormal timing
• The motor lock signal remains LOW for a predetermined continuous period of time while the motor remains stationary.
Remedy: 1 Check the M2 connector for proper connection and correct as necessary. 2 Check the loading status of the fusing unit drive, and correct the error as necessary. 3 Check the fusing unit, PRCB for proper connection and correct or change as necessary. 4 M2 operation check. 5 Change M2. 6 Change PRCB.
Code: C3301
Description: Fusing cooling fan motor/1 failure to turn
• The fan motor lock signal remains HIGH for a predetermined continuous period of time while the motor remains stationary.
Remedy: 1 Check the FM13 connector for proper connection and correct as necessary. 2 Check the fan for possible overload and correct as necessary. 3 FM13 operation check. 4 Change FM13. 5 Change PRCB.