Các lỗi thường gặp

Code :
  • Code: C4153
  • Description: Polygon Motor/Y failure to turn
  • Remedy: 1 Check the connector for proper connection and correct as necessary. 2 Change PH Unit. 3 Change PWB-D. 4 Change PWB-M.
  • Code: C4154
  • Description: Polygon Motor/K failure to turn
  • Remedy: 1 Check the connector for proper connection and correct as necessary. 2 Change PH Unit. 3 Change PWB-D. 4 Change PWB-M.
  • Code: C4551
  • Description: Laser malfunction (Cyan)
    • SOS signal is not detected even after the lapse of a given period of time after staring the laser output.
    • SOS signal is not detected for a given period of time during printing or IDC sensor adjustment.
  • Remedy: 1 Check the connector for proper connection and correct as necessary. 2 Change PH Unit. 3 Change PWB-D. 4 Change PWB-M.
  • Code: C4552
  • Description: Laser malfunction (Magenta)
    • SOS signal is not detected even after the lapse of a given period of time after staring the laser output.
    • SOS signal is not detected for a given period of time during printing or IDC sensor adjustment.
  • Remedy: 1 Check the connector for proper connection and correct as necessary. 2 Change PH Unit. 3 Change PWB-D. 4 Change PWB-M.
  • Code: C4553
  • Description: Laser malfunction (Yellow)
    • SOS signal is not detected even after the lapse of a given period of time after staring the laser output.
    • SOS signal is not detected for a given period of time during printing or IDC sensor adjustment.
  • Remedy: 1 Check the connector for proper connection and correct as necessary. 2 Change PH Unit. 3 Change PWB-D. 4 Change PWB-M.
  • Code: C4554
  • Description: Laser malfunction (Black)
    • SOS signal is not detected even after the lapse of a given period of time after staring the laser output.
    • SOS signal is not detected for a given period of time during printing or IDC sensor adjustment.
  • Remedy: 1 Check the connector for proper connection and correct as necessary. 2 Change PH Unit. 3 Change PWB-D. 4 Change PWB-M.
  • Code: C4705
  • Description: Image Output Time Out
    • No image data is output from the MFP Control Board (PWB-MFP).
  • Remedy: 1 Select [Service Mode] - [State Confirmation] - [Memory/HDD Adj.] - [Memory Bus Check] - [Memory - PRT]. 2 Check the connectors on PWB-MFP for proper connection and correct as necessary. 3 Change PWB-MFP
  • Code: C4761
  • Description: Compression hardware timeout
    • The hardware involved with the compression function offered by the MFP Control Board (PWBMFP) does not respond.
  • Remedy: 1 When the error is displayed after the memory check, remove and insert the DIMM0 and DIMM1 again to recheck (C4765). 2 Change PWB-MFPnge PWB-M