Description: Extraction hardware timeout
• The hardware involved with the extraction function offered by the MFP Control Board (PWBMFP) does not respond.
Remedy: 1 When the error is displayed after the memory check, remove and insert the DIMM0 and DIMM1 again to recheck (C4765). 2 Change PWB-MFPnge PWB-M
Description: JBIG0 Error
• The MFP Control Board (PWB-MFP) is faulty.
Remedy: 1 When the error is displayed after the memory check, remove and insert the DIMM0 and DIMM1 again to recheck (C4765). 2 Change PWB-MFPnge PWB-M
Remedy: 1 When the error is displayed after the memory check, remove and insert the DIMM0 and DIMM1 again to recheck (C4765). 2 Change PWB-MFPnge PWB-M
Description: Main Motor's failure to turn
• The Motor Lock signal remains HIGH for a predetermined continuous period of time while the Motor is turning.
Remedy: 1 Check the M1 connector for proper connection and correct as necessary. 2 Check M1 for proper drive coupling and correct as necessary. 3 Check the PWB-M connector for proper connection and correct as necessary. 4 M1 operation check PWB-M CNDM1-5 (REM) PWB-M CNDM1-8 (LOCK) L-2. 5 Change PWB-M. 6 Change PU1.
Description: Main Motor turning at abnormal timing
• The Motor Lock signal remains LOW for a predetermined continuous period of time while the Motor remains stationary.
Description: Power Supply Cooling Fan Motor/1's failure to turn
• The Fan Lock signal remains HIGH for a predetermined continuous period of time while the Motor remains stationary.
Remedy: 1 Check the connector of motor for proper connection and correct as necessary. 2 Check the fan for possible overload and correct as necessary. 3 M8 operation check PWB-M CNLV3-2 (ON) PWB-M CNLV3-3 (LOCK) C-25. 4 Change PU1.
Description: Cooling Fan Motor 2’s failure to turn
• The Fan Lock signal remains HIGH for a predetermined continuous period of time while the Motor remains stationary.
Remedy: 1 Check the connector of motor for proper connection and correct as necessary. 2 Check the fan for possible overload and correct as necessary. 3 M22 operation check PWB-M CNR2FAN-4 (ON) PWB-M CNR2FAN-6 (LOCK) L-3. 4 Change PWB-M.
Description: Ozone Ventilation Fan Motor's failure to turn
• The Fan Lock signal remains HIGH for a predetermined continuous period of time while the Motor remains stationary.
Remedy: 1 Check the connector of motor for proper connection and correct as necessary. 2 Check the fan for possible overload and correct as necessary. 3 M14 operation check PWB-M CNLP-9 (ON) PWB-M CNLP-11 (LOCK) C-10. 4 Change PWB-MWB-M.
Nhận ưu đãi sớm nhất khi chương trình diễn ra
Đăng ký nhận bản tin
Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này.
Chính sách cookie
Những cookie này là cần thiết để trang web hoạt động đúng cách.
Những cookie này giúp chúng tôi hiểu cách khách truy cập tương tác với trang web.
Những cookie này được sử dụng để cung cấp quảng cáo cá nhân hóa.