Description: Abnormally high toner density detected yellow TCR sensor
• TC ratio in the developing unit, which is determined by toner replenishing amount control mechanism, is a predetermined value or more for a given number of times consecutively.
Remedy: 1 Reinstall developing unit. 2 Reinstall toner cartridge. 3 Check the connector between developing unit-FREYB CN4, CN6, CN8, CN10 for proper connection and correct as necessary. 4 Check the connector between FREYB CN1, CN2-PRCB CN4, CN5 for proper connection and correct as necessary. 5 Change developing unit. 6 Change FREYB. 7 PRCB ICP12 conduction check. 8 Change PRCB.
Description: Abnormally low toner density detected black TCR sensor
• When sampling data is determined in TC ratio calculation control, TCR sensor output is higher than a predetermined value for a predetermined number of times in a row even though there is toner in the sub hopper.
Remedy: 1 Perform image troubleshooting procedure if image density is low. 2 Reinstall developing unit. 3 Reinstall toner cartridge. 4 Check the connector between developing unit-FREYB CN4, CN6, CN8, CN10 for proper connection and correct as necessary. 5 Check the connector between FREYB CN1, CN2-PRCB CN4, CN5 for proper connection and correct as necessary. 6 M6, M7 operation check PRCB CN13-12 to 15 (M6) PRCB CN13-16 to 19 (M7) J-21 7 M8, M9 operation check PRCB CN12-9 to 12 (M8) PRCB CN12-13 to 16 (M9) J-10 8 If the toner empty sensor and its surroundings inside the sub hopper are dirtied with toner, clean them. 9 Change developing unit. 10 Change FREYB. 11 PRCB ICP3,4 conduction check. 12 Change PRCB.
Description: Abnormally high toner density detected black TCR sensor
• TC ratio in the developing unit, which is determined by toner replenishing amount control mechanism, is a predetermined value or more for a given number of times consecutively.
Remedy: 1 Reinstall developing unit. 2 Reinstall toner cartridge. 3 Check the connector between developing unit-FREYB CN4, CN6, CN8, CN10 for proper connection and correct as necessary. 4 Check the connector between FREYB CN1, CN2-PRCB CN4, CN5 for proper connection and correct as necessary. 5 Change developing unit. 6 Change FREYB. 7 PRCB ICP12 conduction check. 8 Change PRCB.
Description: Magenta TCR sensor adjustment failure
• TCR sensor automatic adjustment does not function properly, failing to adjust to an appropriate value
Remedy: 1 Reinstall developing unit. 2 Check the connector between developing unit-FREYB CN4, CN6, CN8, CN10 for proper connection and correct as necessary. 3 Check the connector between FREYB CN1, CN2-PRCB CN4, CN5 for proper connection and correct as necessary. 4 M6, M7 operation check PRCB CN13-12 to 15 (M6) PRCB CN13-16 to 19 (M7) J-21 5 M8, M9 operation check PRCB CN12-9 to 12 (M8) PRCB CN12-13 to 16 (M9) J-10 6 Change developing unit. 7 Change FREYB. 8 PRCB ICP3,4,12 conduction check. 9 Change PRCB.
Description: Yellow TCR sensor adjustment failure
• TCR sensor automatic adjustment does not function properly, failing to adjust to an appropriate value
Remedy: 1 Reinstall developing unit. 2 Check the connector between developing unit-FREYB CN4, CN6, CN8, CN10 for proper connection and correct as necessary. 3 Check the connector between FREYB CN1, CN2-PRCB CN4, CN5 for proper connection and correct as necessary. 4 M6, M7 operation check PRCB CN13-12 to 15 (M6) PRCB CN13-16 to 19 (M7) J-21 5 M8, M9 operation check PRCB CN12-9 to 12 (M8) PRCB CN12-13 to 16 (M9) J-10 6 Change developing unit. 7 Change FREYB. 8 PRCB ICP3,4,12 conduction check. 9 Change PRCB.
Description: Black TCR sensor adjustment failure
• TCR sensor automatic adjustment does not function properly, failing to adjust to an appropriate value
Remedy: 1 Reinstall developing unit. 2 Check the connector between developing unit-FREYB CN4, CN6, CN8, CN10 for proper connection and correct as necessary. 3 Check the connector between FREYB CN1, CN2-PRCB CN4, CN5 for proper connection and correct as necessary. 4 M6, M7 operation check PRCB CN13-12 to 15 (M6) PRCB CN13-16 to 19 (M7) J-21 5 M8, M9 operation check PRCB CN12-9 to 12 (M8) PRCB CN12-13 to 16 (M9) J-10 6 Change developing unit. 7 Change FREYB. 8 PRCB ICP3,4,12 conduction check. 9 Change PRCB.
Description: Cyan TCR sensor failure
• Alarm signals for a TCR sensor are detected more than the predetermined number of times. This detection is used for detecting disconnection of TCR sensor connector.
Remedy: 1 Reinstall developing unit. 2 Check the connector between developing unit-FREYB CN4, CN6, CN8, CN10 for proper connection and correct as necessary. 3 Check the connector between FREYB CN1, CN2-PRCB CN4, CN5 for proper connection and correct as necessary. 4 Change developing unit. 5 Change FREYB. 6 Change PRCB.
Nhận ưu đãi sớm nhất khi chương trình diễn ra
Đăng ký nhận bản tin
Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này.
Chính sách cookie
Những cookie này là cần thiết để trang web hoạt động đúng cách.
Những cookie này giúp chúng tôi hiểu cách khách truy cập tương tác với trang web.
Những cookie này được sử dụng để cung cấp quảng cáo cá nhân hóa.