  • Code: C2562
  • Description: Magenta TCR sensor failure
    • Alarm signals for a TCR sensor are detected more than the predetermined number of times. This detection is used for detecting disconnection of TCR sensor connector.
  • Remedy: 1 Reinstall developing unit. 2 Check the connector between developing unit-FREYB CN4, CN6, CN8, CN10 for proper connection and correct as necessary. 3 Check the connector between FREYB CN1, CN2-PRCB CN4, CN5 for proper connection and correct as necessary. 4 Change developing unit. 5 Change FREYB. 6 Change PRCB.
  • Code: C2563
  • Description: Yellow TCR sensor failure
    • Alarm signals for a TCR sensor are detected more than the predetermined number of times. This detection is used for detecting disconnection of TCR sensor connector.
  • Remedy: 1 Reinstall developing unit. 2 Check the connector between developing unit-FREYB CN4, CN6, CN8, CN10 for proper connection and correct as necessary. 3 Check the connector between FREYB CN1, CN2-PRCB CN4, CN5 for proper connection and correct as necessary. 4 Change developing unit. 5 Change FREYB. 6 Change PRCB.
  • Code: C2564
  • Description: Black TCR sensor failure
    • Alarm signals for a TCR sensor are detected more than the predetermined number of times. This detection is used for detecting disconnection of TCR sensor connector.
  • Remedy: 1 Reinstall developing unit. 2 Check the connector between developing unit-FREYB CN4, CN6, CN8, CN10 for proper connection and correct as necessary. 3 Check the connector between FREYB CN1, CN2-PRCB CN4, CN5 for proper connection and correct as necessary. 4 Change developing unit. 5 Change FREYB. 6 Change PRCB.
  • Code: C2650
  • Description: Main backup media access error
    • Contact the responsible people of KMBT before taking some countermeasures.
  • Remedy: 1 Check the connector (CN23) on PRCB, the connector (CN1) on SV ERB, and the harness between the boards for proper connection and correct as necessary. 2 Change PRCB 1. Turn OFF the main power switch and replace the current PRCB with a new one. (When using a PRCB of another machine in service, be sure to use a PRCB installed in the same model.) 2. Update the PRCB firmware. 3. After completing the firmware update, turn OFF and ON the main power switch and check to see that warm-up is started. Make sure that malfunction codes other than C2650 or improper IU/TC placement is not detected. 4. When the trouble cannot be solved, reinstall the removed PRCB to the original board. NOTE • When taking the above steps, check whether PRCB is defective or not without replacing the SV ERB. 3 Change SV ERB 1. Replace the current SV ERB with a new one. 2. Turn ON the main power switch and check to see that warm-up is started. (One minute is spent to prepare the new SV ERB for use. During the period, the control panel backlight stays off.) Make sure that malfunction codes other than C2650 or improper IU/TC placement is not detected. 3. Make the specified readjustments. 4 If the above actions do not solve the problem, contact KMBT.
  • Code: C2A11
  • Description: Drum unit/C new release failure
    • The status with the new unit is not cleared after the new drum unit is set.
  • Remedy: 1 Clean the connection between the drum unit and the machine if dirty. 2 Reinstall drum unit. 3 Check the connector between drum unit- FREYB CN5, CN7, CN9, CN11 for proper connection and correct as necessary. 4 Check the connector between FREYB CN1, CN2-PRCB CN4, CN5 for proper connection and correct as necessary. 5 Change drum unit. 6 Change FREYB. 7 PRCB ICP12 conduction check. 8 Change PRCB.
  • Code: C2A12
  • Description: Drum unit/M new release failure
  • Remedy: 1 Clean the connection between the drum unit and the machine if dirty. 2 Reinstall drum unit. 3 Check the connector between drum unit- FREYB CN5, CN7, CN9, CN11 for proper connection and correct as necessary. 4 Check the connector between FREYB CN1, CN2-PRCB CN4, CN5 for proper connection and correct as necessary. 5 Change drum unit. 6 Change FREYB. 7 PRCB ICP12 conduction check. 8 Change PRCB.
  • Code: C2A13
  • Description: Drum unit/Y new release failure
  • Remedy: 1 Clean the connection between the drum unit and the machine if dirty. 2 Reinstall drum unit. 3 Check the connector between drum unit- FREYB CN5, CN7, CN9, CN11 for proper connection and correct as necessary. 4 Check the connector between FREYB CN1, CN2-PRCB CN4, CN5 for proper connection and correct as necessary. 5 Change drum unit. 6 Change FREYB. 7 PRCB ICP12 conduction check. 8 Change PRCB.
  • Code: C2A14
  • Description: Drum unit/K new release failure
  • Remedy: 1 Clean the connection between the drum unit and the machine if dirty. 2 Reinstall drum unit. 3 Check the connector between drum unit- FREYB CN5, CN7, CN9, CN11 for proper connection and correct as necessary. 4 Check the connector between FREYB CN1, CN2-PRCB CN4, CN5 for proper connection and correct as necessary. 5 Change drum unit. 6 Change FREYB. 7 PRCB ICP12 conduction check. 8 Change PRCB.