Description: Fusing abnormally high temperature detection (Pressurizing side)
• Detected temperature of the pressure roller thermistor goes beyond a given temperature for a given period of time consecutively.
Remedy: 1 Check the fusing unit for correct installation (whether it is secured in position). 2 Check the open/close operation of the right door. 3 Check the fusing unit, DCPU and PRCB for proper connection and correct or change as necessary. 4 Change fusing unit. 5 Change PRCB. 6 Change DCPU.
Description: Fusing abnormally low temperature detection (Heating side)
• Detected temperature of the heating roller thermistor/C goes below a given temperature for a given period of time consecutively after warm up is completed. • Detected temperature of the heating roller thermistor/M goes below a given temperature for a given period of time consecutively after warm up is completed.
Remedy: 1 Check the fusing unit for correct installation (whether it is secured in position). 2 Check the open/close operation of the right door. 3 Check the fusing unit, DCPU and PRCB for proper connection and correct or change as necessary. 4 Change fusing unit. 5 Change PRCB. 6 Change DCPU.
Description: Fusing abnormally low temperature detection (Pressurizing side)
• Detected temperature of the pressure roller thermistor goes below a given temperature for a given period of time consecutively after warm up is completed.
Remedy: 1 Check the fusing unit for correct installation (whether it is secured in position). 2 Check the open/close operation of the right door. 3 Check the fusing unit, DCPU and PRCB for proper connection and correct or change as necessary. 4 Change fusing unit. 5 Change PRCB. 6 Change DCPU.
Description: Fusing sensor wire breaks detection (Heating side)
• The maximum value and minimum value of detected temperature of the heating roller thermistor/C, M and S are compared after a lapse of given time from starting of warm up and the gap between the value of maximum and minimum of either thermistor is below or over a given temperature. • The detected temperature gap between the heating roller thermistor /C and the heating roller thermistor/M surpasses a given temperature.
Remedy: 1 Check the fusing unit for correct installation (whether it is secured in position). 2 Check the open/close operation of the right door. 3 Check the fusing unit, DCPU and PRCB for proper connection and correct or change as necessary. 4 Change fusing unit. 5 Change PRCB. 6 Change DCPU.
Description: Fusing sensor wire breaks detection (Pressurizing side)
• The maximum value and minimum value of detected temperature of the pressure roller thermistor are compared after a lapse of given time from starting of warm up and the gap between the value of maximum and minimum is below or over a given temperature. • The pressure heater lights up for a given period of time consecutively.
Remedy: 1 Check the fusing unit for correct installation (whether it is secured in position). 2 Check the open/close operation of the right door. 3 Check the fusing unit, DCPU and PRCB for proper connection and correct or change as necessary. 4 Change fusing unit. 5 Change PRCB. 6 Change DCPU.
Description: Polygon motor rotation trouble
• The polygon motor fails to turn stably even after the lapse of a given period of time after activating the polygon motor. • Motor lock signal detects HIGH for a given period time consecutively during the polygon motor is rotating.
Remedy: 1 Check the connector between PH unit- PHREYB CN6 for proper connection and correct as necessary. 2 Check the connector between PHREYB CN3-PRCB CN26 for proper connection and correct as necessary. 3 Change PH unit. 4 PHREYB ICP1 conduction check. 5 Change PHREYB. 6 Change PRCB.
Description: Laser malfunction
• SOS signal is not detected even after the lapse of a given period of time after staring the laser output. • SOS signal is not detected for a given period of time during printing or IDC sensor adjustment.
Remedy: 1 Check the connector between PH unit- PHREYB CN5 for proper connection and correct as necessary. 2 Check the connector between PHREYB CN2-PRCB CN25 for proper connection and correct as necessary. 3 Change PH unit. 4 PRCB ICP12 conduction check. 5 Change PHREYB. 6 Change PRCB.
Description: Transport motor’s failure to turn
• The motor lock signal remains HIGH for a predetermined continuous period of time while the motor remains stationary.
Remedy: 1 Check the connector between M1-PRCB CN14 for proper connection and correct as necessary. 2 Check M1 for proper drive coupling and correct as necessary. 3 M1 operation check PRCB CN14-2 (REM) PRCB CN14-5 (LOCK) C-2 to 5. 4 Change M1. 5 Change PRCB.
Nhận ưu đãi sớm nhất khi chương trình diễn ra
Đăng ký nhận bản tin
Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này.
Chính sách cookie
Những cookie này là cần thiết để trang web hoạt động đúng cách.
Những cookie này giúp chúng tôi hiểu cách khách truy cập tương tác với trang web.
Những cookie này được sử dụng để cung cấp quảng cáo cá nhân hóa.