Description: Pressure/retraction mechanism failure at the turnover section See DF-608
Remedy:
Code: C8103
Description: Lift up mechanism failure See DF-608
Remedy:
Code: C8104
Description: Original glass travel failure See DF-608
Remedy:
Code: C8105
Description: Original feeding interval failure See DF-608
Remedy:
Code: C8302
Description: Cooling fan failure See DF-608
Remedy:
Code: C9401
Description: Exposure lamp’s failure to turn ON
• The output from the CCD sensor is a predetermined value or less during CCD sensor gain adjustment.
Remedy: 1 Check the flat cable for proper connection and correct or change as necessary. 2 Change scanner assy. 3 Change IPB MFPB.
Code: C9402
Description: Exposure lamp turning ON at abnormal timing
• The average output value of the CCD sensor with the scanner at its standby position is a predetermined value or more at the end of a scan job.
Remedy: 1 Check the flat cable for proper connection and correct or change as necessary. 2 Change scanner assy. 3 Change IPB MFPB.
Code: CA051
Description: Standard controller configuration failure
• The controller of the printer control board (PRCB) is faulty.
Remedy: 1 Check to see if the following setting has been correctly made: [Service Mode] - [System 2] - [Image Controller Setting]. If changing the setting, turn OFF the main power switch and turn it ON again after 10 seconds or more. 2 Check the connectors of the printer control board (PRCB) for proper connection and correct as necessary. 3 Change PRCB.