Description: Abnormally high toner density detected magenta TCR sensor
• TC ratio in the developing machine, which is determined by toner replenishing amount control mechanism, is 12 % or more for a given number of times consecutively.
Remedy: 1 Clean the TCR sensor window on the underside of the imaging unit if dirty 2 Reinstall imaging unit. 3 Change imaging unit. 4 Change MFPB. 5 Change PRCB.
Description: Abnormally low toner density detected yellow TCR sensor
• TC ratio in the developing machine, which is determined by toner replenishing amount control mechanism, is 5 % or less for a given number of times consecutively.
Remedy: 1 Perform image troubleshooting procedure if image density is low. 2 Clean the TCR sensor window on the underside of the imaging unit if dirty 3 M6, M7 operation check MFPB CNDM2-10 to 13 (M6) MFPB CNDM3-10 to 13 (M7) C-20 C-21. 4 Reinstall imaging unit. 5 Change imaging unit. 6 Change MFPB. 7 Change PRCB.
Description: Abnormally high toner density detected yellow TCR sensor
• TC ratio in the developing machine, which is determined by toner replenishing amount control mechanism, is 12 % or more for a given number of times consecutively.
Remedy: 1 Clean the TCR sensor window on the underside of the imaging unit if dirty 2 Reinstall imaging unit. 3 Change imaging unit. 4 Change MFPB. 5 Change PRCB
Description: Abnormally low toner density detected black TCR sensor
• TC ratio in the developing machine, which is determined by toner replenishing amount control mechanism, is 4 % or less for a given number of times consecutively.
Remedy: 1 Perform image troubleshooting procedure if image density is low. 2 Clean the TCR sensor window on the underside of the imaging unit if dirty 3 M7 operation check MFPB CNDM3-10 to 13 C-21 4 Reinstall Imaging unit. 5 Change imaging unit /K. 6 Change MFPB. 7 Change PRCB.
Description: Abnormally high toner density detected black TCR sensor
• TC ratio in the developing machine, which is determined by toner replenishing amount control mechanism, is 12 % or more for a given number of times consecutively.
Remedy: 1 Correct the TCR connection on the underside of the imaging unit if faulty. 2 Reinstall imaging unit. 3 Change imaging unit. 4 Change MFPB. 5 Change PRCB.
Description: Cyan TCR sensor adjustment failure
• TCR sensor automatic adjustment does not function properly, failing to adjust to an appropriate value.
Remedy: 1 Clean the TCR sensor window on the underside of the imaging unit if dirty 2 M6, M7 operation check MFPB CNDM2-10 to 13 (M6) MFPB CNDM3-10 to 13 (M7) C-20 C-21. 3 Reinstall imaging unit. 4 Change imaging unit. 5 Change MFPB. 6 Change PRCB.
Remedy: 1 Clean the TCR sensor window on the underside of the imaging unit if dirty 2 M6, M7 operation check MFPB CNDM2-10 to 13 (M6) MFPB CNDM3-10 to 13 (M7) C-20 C-21. 3 Reinstall imaging unit. 4 Change imaging unit. 5 Change MFPB. 6 Change PRCB.
Remedy: 1 Clean the TCR sensor window on the underside of the imaging unit if dirty 2 M6, M7 operation check MFPB CNDM2-10 to 13 (M6) MFPB CNDM3-10 to 13 (M7) C-20 C-21. 3 Reinstall imaging unit. 4 Change imaging unit. 5 Change MFPB. 6 Change PRCB.
Nhận ưu đãi sớm nhất khi chương trình diễn ra
Đăng ký nhận bản tin
Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này.
Chính sách cookie
Những cookie này là cần thiết để trang web hoạt động đúng cách.
Những cookie này giúp chúng tôi hiểu cách khách truy cập tương tác với trang web.
Những cookie này được sử dụng để cung cấp quảng cáo cá nhân hóa.