Description: HDD access error. When correct access to the hard disk kit is failed during access.
Causes: • MFP board (MFPB) • Hard disk kit (HD-P06)
Remedy: 1 Reboot the main body. 2 Check the HD-P06 connector for proper connection and correct as necessary. 3 Check the MFPB connector for proper connection and correct as necessary. 4 Replace HD-P06. 5 Replace MFPB.
Description: HDD full error Range for user space is full during access to the hard disk kit.
Causes: • MFP board (MFPB) • Hard disk kit (HD-P06)
Remedy: 1 Reboot the main body. 2 Delete the job hold in [PROOF/PRINT MENU] to increase the available range for user space. 3 Check the HD-P06 connector for proper connection and correct as necessary. 4 Format HD-P06 with [ADMIN SETTINGS] - [SYSTEM SETTINGS] -> [SECURITY SETTINGS] -> [HDD SETTINGS] -> [HDD FORMAT]. 5 Replace HD-P06. 6 Replace MFPB.
Description: Firmware update error Firmware update fails to complete correctly during update.
Causes: MFP board (MFPB)
Remedy: 1 Reboot the main body. 2 Check the cable that has been used for update of the firmware for proper connection and correct as necessary. 3 Check the firmware update file and if the file is not the correct one, update the firmware again. 4 Check the firmware update procedure and if the procedure is not correct, update the firmware again. 5 Update the firmware again. 6 Check the MFPB connector for proper connection and correct as necessary. 7 Replace MFPB.
Description: Counter error A write error occurs in the counter area.
Causes: MFP board (MFPB)
Remedy: 1 Check the MFPB for its mounting condition and correct any faulty condition. 2 Replace MFPB. 3 If the same trouble code persists after the abovementioned procedures, the EEPROM is probably damaged.
Description: Successful completion of counter backup The counter backup process is completed successfully.
Causes:
Remedy: 1 This code is displayed when the counter backup process is completed successfully. When this code is displayed, turn OFF/ON the power switch and then perform the given steps. G.5.10 MFP board (MFPB)
Description: Abnormal end of counter backup The counter backup process results in an abnormal end due to a write error or other reasons.
Causes: MFP board (MFPB)
Remedy: 1. Reboot the main body. 2 Check the MFPB connector for proper connection and correct as necessary. 3 Replace MFPB. 4 After taking the above actions, if the counter backup process results in the same trouble code again, the EEPROM can be broken. In this case, the counter backup is unavailable.
Nhận ưu đãi sớm nhất khi chương trình diễn ra
Đăng ký nhận bản tin
Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này.
Chính sách cookie
Những cookie này là cần thiết để trang web hoạt động đúng cách.
Những cookie này giúp chúng tôi hiểu cách khách truy cập tương tác với trang web.
Những cookie này được sử dụng để cung cấp quảng cáo cá nhân hóa.