Description: 2nd image transfer pressure / retraction failure
• The retraction position sensor /2 is not activated (retracted position) within a given period of time after the retraction sequence of the 2nd transfer roller has been started.
• The retraction position sensor /2 is not deactivated (pressed position) within a given period of time after the pressure sequence of the 2nd transfer roller has been started.
Remedy: 1 Check the M3 connector for proper connection and correct as necessary. 2 Check the CL5 connector for proper connection and correct as necessary. 3 Check M3 for proper drive coupling and correct as necessary. 4 Check CL5 for proper drive coupling and correct as necessary. 5 Check the MFPB connector for proper connection and correct as necessary. 6 PS10 sensor check. 7 CL5 operation check. 8 M3 operation check. 9 Change M3. 10 Change CL5. 11 Change MFPB.
Code: 0096
Display: XFER DETACH 1
Description: 1st image transfer pressure / retraction failure
• The retraction position sensor /1 is not activated (retracted position) within a given period of time after the intermediate transport motor has started rotating.
• The retraction position sensor /1 is not deactivated (pressed position) within a given period of time after the intermediate transport motor has started rotating.
Remedy: 1 Check the M3 connector for proper connection and correct as necessary. 2 Check the CL4 connector for proper connection and correct as necessary. 3 Check M3 for proper drive coupling and correct as necessary. 4 Check CL4 for proper drive coupling and correct as necessary. 5 Check the MFPB connector for proper connection and correct as necessary. 6 PS9 sensor check. 7 CL4 operation check. 8 M3 operation check. 9 Change M3. 10 Change CL4. 11 Change MFPB.
Code: 0300
Display: POLYGON MOTOR
Description: Polygon motor malfunction
• The polygon motor does not rotate evenly even after the lapse of a given period of time after it has been started.
• The motor lock signal remains HIGH for a given period of consecutive time while the polygon motor is being rotated.
Remedy: 1 Check the cable and connector for proper connection and correct as necessary. 2 Change PH unit. 3 Change MFPB.
Code: 0310
Display: LASER ERROR
Description: Laser malfunction
• The SOS signal is not detected within a given period of time after the output of the laser has been started.
Remedy: 1 Check the cable and connector for proper connection and correct as necessary. 2 Change PH unit. 3 Change MFPB.
Code: 0500
Display: FUSER ERROR
Description: Heating roller warm-up failure
• The thermistor /1 does not detect the specified temperature and the warm-up cycle is not completed even after the lapse of a given period of time after the cycle has been started.
Remedy: 1 Check the fusing unit for correct installation (whether it is secured in position). 2 Check the fusing unit, DCPU, and MFPB for proper connection and correct as necessary. 3 Change fusing unit. 4 Change MFPB. 5 Change DCPU.
Code: 0501
Display: FUSER ERROR
Description: Fusing pressure roller warm-up failure
• The thermistor /2 does not detect the specified temperature and the warm-up cycle is not completed even after the lapse of a given period of time after the cycle has been started.
Remedy: 1 Check the fusing unit for correct installation (whether it is secured in position). 2 Check the fusing unit, DCPU, and MFPB for proper connection and correct as necessary. 3 Change fusing unit. 4 Change MFPB. 5 Change DCPU.
Code: 0510
Display: FUSER ERROR
Description: Abnormally low heating roller temperature
• The temperature detected by the thermistor /1 remains lower than the specified value for a given period of time or longer.
Remedy: 1 Check the fusing unit for correct installation (whether it is secured in position). 2 Check the fusing unit, DCPU, and MFPB for proper connection and correct as necessary. 3 Change fusing unit. 4 Change MFPB. 5 Change DCPU.
Code: 0511
Display: FUSER ERROR
Description: Abnormally low fusing pressure roller temperature
• The temperature detected by the thermistor /2 remains lower than the specified value for a given period of time or longer.
Remedy: 1 Check the fusing unit for correct installation (whether it is secured in position). 2 Check the fusing unit, DCPU, and MFPB for proper connection and correct as necessary. 3 Change fusing unit. 4 Change MFPB. 5 Change DCPU.