Description: Abnormally low toner density detected Magenta TCR Sensor
• T/C 0.21 % or less is detected ten consecutive times in the Developing Unit as validated through the toner replenishing amount determination control.
Remedy: 1 Perform image troubleshooting procedure if image density is low. 2 Clean the TCR Sensor window on the underside of the Imaging Unit if dirty 3 Correct the TCR Sensor spring moving part if faulty. 4 Clean the TCR Sensor LED if dirty. 5 Change TCR Sensor C/M/Y. 6 M3, M4 operation check PWB-MC PJ8MC-1 to 4 PWB-MC PJ8MC-5 to 8. 7 Change Imaging Unit. 8 Change PWB-MC. 9 Change PWB-MFPC.
Description: Abnormally high toner density detected Magenta TCR Sensor
• T/C 15.5 % or more is detected ten consecutive times in the Developing Unit as validated through the toner replenishing amount determination control.
Remedy: 1 Clean the TCR Sensor window on the underside of the Imaging Unit if dirty 2 Clean the TCR Sensor LED if dirty. 3 Correct the contact and/or WIRING of the TCR Sensor if faulty. 4 Change TCR Sensor C/M/Y. 5 Change Imaging Unit. 6 Change PWB-MC. 7 Change PWB-MFPC.
Description: Abnormally low toner density detected Yellow TCR Sensor
• T/C 0.21 % or less is detected ten consecutive times in the Developing Unit as validated through the toner replenishing amount determination control.
Remedy: 1 Perform image troubleshooting procedure if image density is low. 2 Clean the TCR Sensor window on the underside of the Imaging Unit if dirty 3 Correct the TCR Sensor spring moving part if faulty. 4 Clean the TCR Sensor LED if dirty. 5 Change TCR Sensor C/M/Y. 6 M3, M4 operation check PWB-MC PJ8MC-1 to 4 PWB-MC PJ8MC-5 to 8. 7 Change Imaging Unit. 8 Change PWB-MC. 9 Change PWB-MFPC.
Description: Abnormally high toner density detected Yellow TCR Sensor
• T/C 15.5 % or more is detected ten consecutive times in the Developing Unit as validated through the toner replenishing amount determination control.
Remedy: 1 Clean the TCR Sensor window on the underside of the Imaging Unit if dirty 2 Clean the TCR Sensor LED if dirty. 3 Correct the contact and/or WIRING of the TCR Sensor if faulty. 4 Change TCR Sensor C/M/Y. 5 Change Imaging Unit. 6 Change PWB-MC. 7 Change PWB-MFPC.
Description: Abnormally low toner density detected Black TCR Sensor
• T/C 3 % or less is detected ten consecutive times in the Developing Unit as validated through the toner replenishing amount determination control.
Remedy: 1 Perform image troubleshooting procedure if image density is low. 2 M3 operation check PWB-MC PJ8MC-1 to 4 C to D-14 3 Change Imaging Unit. 4 Change PWB-MC. 5 Change PWB-MFPC.
Description: Abnormally high toner density detected Black TCR Sensor
• T/C 12 % or more is detected ten consecutive times in the Developing Unit as validated through the toner replenishing amount determination control.
Remedy: 1 Correct the TCR connection on the underside of the Imaging Unit if faulty. 2 Clean or correct each contact of the Imaging Unit if faulty. 3 Change Imaging Unit. 4 Change PWB-MC. 5 Change PWB-MFPC.
Description: Cyan TCR Sensor adjustment failure
• TCR Sensor automatic adjustment does not function properly, failing to adjust to an appropriate value.
Remedy: 1 Clean the TCR Sensor window on the underside of the Imaging Unit if dirty 2 Clean the TCR Sensor LED if dirty. 3 Correct the contact and/or WIRING of the TCR Sensor if faulty. 4 Reinstall Imaging Unit C/M/Y. 5 M3, M4 operation check PWB-MC PJ8MC-1 to 4 PWB-MC PJ8MC-5 to 8 C to D-14. 6 Change Imaging Unit. 7 Change PWB-MC. 8 Change PWB-MFPC.
Remedy: 1 Clean the TCR Sensor window on the underside of the Imaging Unit if dirty 2 Clean the TCR Sensor LED if dirty. 3 Correct the contact and/or WIRING of the TCR Sensor if faulty. 4 Reinstall Imaging Unit C/M/Y. 5 M3, M4 operation check PWB-MC PJ8MC-1 to 4 PWB-MC PJ8MC-5 to 8 C to D-14. 6 Change Imaging Unit. 7 Change PWB-MC. 8 Change PWB-MFPC.
Nhận ưu đãi sớm nhất khi chương trình diễn ra
Đăng ký nhận bản tin
Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này.
Chính sách cookie
Những cookie này là cần thiết để trang web hoạt động đúng cách.
Những cookie này giúp chúng tôi hiểu cách khách truy cập tương tác với trang web.
Những cookie này được sử dụng để cung cấp quảng cáo cá nhân hóa.