Description: Suction fan motor’s failure to turn
• The fan lock signal remains HIGH for a predetermined continuous period of time while the motor remains stationary.
Remedy: 1 Check the connector of motor for proper connection and correct as necessary. 2 Check the fan for possible overload and correct as necessary. 3 M12 operation check PWB-MC PJ13MC-7 (REM) PWB-MC PJ13MC-9 (LOCK) C to D-2. 4 Change PWB-MC.
Code: C0351
Description: Paper Cooling Fan Motor's failure to turn
• The Fan Lock signal remains HIGH for a predetermined continuous period of time while the Motor remains stationary
Remedy: 1 Check the connector of motor for proper connection and correct as necessary. 2 Check the fan for possible overload and correct as necessary. 3 M26 operation check PWB-MC PJ7MC-8 (REM) PWB-MC PJ7MC-10 (LOCK) K-8. 4 Change PWB-MC.
Code: C1180
Description: Finishing option transport system malfunction
Remedy:
Code: C1181
Description: Finishing option Paddle Motor malfunction