Description: Transfer belt contact fault at all pressure switching The 1st transfer pressure sensor (PS9) does not detect “switch from retraction to pressure” within a given period time after the 1st transfer pressure solenoid (SD1) turned ON.
Causes: • Main motor (M1) • 1st transfer pressure solenoid (SD1) • 1st transfer pressure sensor (PS9) • MFP board (MFPB)
Remedy: 1. Check the connector between M1-MFPB CN6E for proper connection and correct as necessary. 2. Check the connector of M1 for proper drive coupling and correct as necessary. 3. Check the connector between PS9-MFPB CN9E for proper connection and correct as necessary. 4. Check the connector between SD1-relay CN85-MFPB CN9E for proper connection and correct as necessary. 5. PS9 I/O check, sensor check • Control signal: MFPB CN9E-3 (ON) • Location of electrical component: 3-C 6. SD1 operation check • Control signal: MFPB CN9E-12 (REM) • Location of electrical component: 4-C 7. M1 operation check • Control signal: MFPB CN6E-4 to 7 • Location of electrical component: 2-C 8. Replace M1. 9. MFPB F4E conduction check 10. Replace MFPB.
Code: C2155
Description: Transfer belt contact fault after K pressure established The 1st transfer pressure sensor (PS9) is turned ON (blocked) after the lamps of given time after the 1st transfer pressure solenoid (SD1) turned OFF when the release operation is finished.
Causes: • Main motor (M1) • 1st transfer pressure solenoid (SD1) • 1st transfer pressure sensor (PS9) • MFP board (MFPB)
Remedy: 1. Check the connector between M1-MFPB CN6E for proper connection and correct as necessary. 2. Check the connector of M1 for proper drive coupling and correct as necessary. 3. Check the connector between PS9-MFPB CN9E for proper connection and correct as necessary. 4. Check the connector between SD1-relay CN85-MFPB CN9E for proper connection and correct as necessary. 5. PS9 I/O check, sensor check • Control signal: MFPB CN9E-3 (ON) • Location of electrical component: 3-C 6. SD1 operation check • Control signal: MFPB CN9E-12 (REM) • Location of electrical component: 4-C 7. M1 operation check • Control signal: MFPB CN6E-4 to 7 • Location of electrical component: 2-C 8. Replace M1. 9. MFPB F4E conduction check 10. Replace MFPB.
Code: C2156
Description: Transfer belt spacing fault after all pressure established The 1st transfer pressure sensor (PS9) is turned OFF (unblocked) after the laps of given time after the 1st transfer pressure solenoid (SD1) turned OFF when the pressing operation is finished.
Causes: • Main motor (M1) • 1st transfer pressure solenoid (SD1) • 1st transfer pressure sensor (PS9) • MFP board (MFPB)
Remedy: 1. Check the connector between M1-MFPB CN6E for proper connection and correct as necessary. 2. Check the connector of M1 for proper drive coupling and correct as necessary. 3. Check the connector between PS9-MFPB CN9E for proper connection and correct as necessary. 4. Check the connector between SD1-relay CN85-MFPB CN9E for proper connection and correct as necessary. 5. PS9 I/O check, sensor check • Control signal: MFPB CN9E-3 (ON) • Location of electrical component: 3-C 6. SD1 operation check • Control signal: MFPB CN9E-12 (REM) • Location of electrical component: 4-C 7. M1 operation check • Control signal: MFPB CN6E-4 to 7 • Location of electrical component: 2-C 8. Replace M1. 9. MFPB F4E conduction check 10. Replace MFPB.
Code: C2253
Description: Color PC motor failure to turn The motor lock signal remains HIGH for a predetermined continuous period of time while the motor is turning.
Causes: • Color PC motor (M4) • MFP board (MFPB)
Remedy: 1. Check the connector between M4-MFPB CN4E for proper connection and correct as necessary. 2. Check the M4 connector for proper drive coupling and correct as necessary. 3. M4 operation check • Control signal: MFPB CN4E-11 to 13 • Location of electrical component: 25 to 26-C 4. Replace M4. 5. MFPB F7E conduction check 6. Replace MFPB.
Code: C2254
Description: Color PC motor turning at abnormal timing The motor lock signal remains LOW for a predetermined continuous period of time while the motor remains stationary.
Causes: • Color PC motor (M4) • MFP board (MFPB)
Remedy: 1. Check the connector between M4-MFPB CN4E for proper connection and correct as necessary. 2. Check the M4 connector for proper drive coupling and correct as necessary. 3. M4 operation check • Control signal: MFPB CN4E-11 to 13 • Location of electrical component: 25 to 26-C 4. Replace M4. 5. MFPB F7E conduction check 6. Replace MFPB.
Code: C2255
Description: Developing motor failure to turn (color) The motor lock signal remains HIGH for a predetermined continuous period of time while the motor is turning.
Causes: • Developing motor (M3) • MFP board (MFPB)
Remedy: 1. Check the connector between M3-MFPB CN4E for proper connection and correct as necessary. 2. Check the connector of M3 for proper drive coupling and correct as necessary. 3. M3 operation check • Control signal: MFPB CN4E-4 to 7 • Location of electrical component: 25-C 4. Replace M3. 5. MFPB F7E conduction check 6. Replace MFPB.
Code: C2256
Description: Developing motor turning at abnormal timing (color) The motor lock signal remains LOW for a predetermined continuous period of time while the motor remains stationary.
Causes: • Developing motor (M3) • MFP board (MFPB)
Remedy: 1. Check the connector between M3-MFPB CN4E for proper connection and correct as necessary. 2. Check the connector of M3 for proper drive coupling and correct as necessary. 3. M3 operation check • Control signal: MFPB CN4E-4 to 7 • Location of electrical component: 25-C 4. Replace M3. 5. MFPB F7E conduction check 6. Replace MFPB.
Code: C2259
Description: Developing motor failure to turn (K) The motor lock signal remains HIGH for a predetermined continuous period of time while the motor is turning.
Causes: • Developing motor (M3) • MFP board (MFPB)
Remedy: 1. Check the connector between M3-MFPB CN4E for proper connection and correct as necessary. 2. Check the connector of M3 for proper drive coupling and correct as necessary. 3. M3 operation check • Control signal: MFPB CN4E-4 to 7 • Location of electrical component: 25-C 4. Replace M3. 5. MFPB F7E conduction check 6. Replace MFPB.