Thương hiệu phân phối chính hãng
Giỏ hàng

Mã lỗi Konica-Minolta bizhub C554e — Trang 26/29

Code: CD212

Description: Compression/extraction timeout detection. Hardware related to the BTC compression function of the MFP board (MFPB) fails to respond.
Remedy: 1 Replace MFPB.

Code: CD241, CD242

Description: Encryption ASIC setting error. Encryption ASIC mounting error.
Remedy: 1 Check the MFP board connector for proper connection and correct as necessary. - - 2 Replace MFPB.

Code: CD252

Description: No relay circuit boards for IC-414 mounting at IC-414 mount setting. EFI relay circuit boards (VI-506) are not mounted when the IC-414 is set to mount setting at Service Mode.
Remedy: • MFP board (MFPB) • EFI relay board (VI-506) 1 If the IC-414 is not mounted, access [Service Mode] -> [System 2] -> [Image Controller Setting] and check to see if “Controller 0” is set for [Image Controller Setting]. - - 2 Check the EFI relay board (VI-506) connector for proper connection and correct as necessary. - - 3 Replace EFI relay board (VI-506) - - 4 Replace MFPB.

Code: CD261

Description: USB host board failure. • When a failure is detected in USB host board included in the local interface kit. • Non-standard USB device is connected.
Remedy: • MFP board (MFPB) • USB host board (EK-606) • USB host board (EK-607) 1 Check the operation with another USB device. - - 2 Check the USB host board connector for proper connection and correct as necessary. - - 3 Replace the USB host board - - 4 Replace MFPB.

Code: CD262

Description: Extension network adapter installation error. • When the 2nd network card settings is set to “Set” but the upgrade kit (UK-208) is not installed. • Upgrade Kit (UK-208) is faulty.
Remedy: 1 Check the settings of the Service Mode. [Service Mode] -> [Network Settings] -> [2nd Network Setting] -> [2nd network card settings] - - 2 Check the UK-208 connector for proper connection and correct as necessary. - - 3 Check the UK-209 and DSIPB for proper connection and correct as necessary. - - 4 Update the PRCB firmware. - - 5 Reinstall the UK-208. - - 6 Reinstall the UK-209 or DSIPB.

Code: CD271

Description: i-Option activated and additional memory not installed. While the i-Option is activated, the additional memory included in UK-204 is not installed.
Remedy: • MFP board (MFPB) • Memory board/2 (MEMB/2; UK-204) 1 Check the MEMB/2 for proper connection and correct as necessary. - - 2 Replace MEMB/2 - - 3 Replace MFPB.

Code: CD272

Description: i-Option activated and additional memory and HDD not installed. While the i-Option is activated, the additional memory included in UK-204 and the HDD are not installed.
Remedy: • MFP board (MFPB) • Hard disk • Memory board/2 (MEMB/2; UK-204) 1 Check MEMB/2 for proper connection and correct as necessary. - - 2 Access [Service Mode] -> [System 2] -> [HDD] and check to see if “Installed” is selected. - - 3 Replace MEMB/2 - - 4 Replace the hard disk. - - 5 Replace MFPB

Code: CD370

Description: Nonvolatile data multiple errors. Multiple errors (over 5) are detected by the abnormal check of each nonvolatile data.
Remedy: • Trouble code [C-D370] will be displayed when multiple errors (over 5) of nonvolatile data are detected, which can be restored with one restoration command. • Data backup will be automatically performed every hour. Backup can also be performed manually with the following setting. [Service Mode] -> [Enhanced Security] -> [Memory Data Backup] 1. When a trouble caused by nonvolatile data error occurs, the screen below appears. 2. Select [Yes]. 3. The screen will be shifted to the data restoration screen to perform data restoration. NOTE • When the restoration is performed in a short time, data restoration screen may not be displayed. 4. Check the message which indicates that the data restoration was successfully conducted. Turn OFF the main power switch and turn it ON again more than 10 seconds after. NOTE • In case it failed to restore data, return to the trouble code screen.