Code: C8302

Description: Take-up cooling fan failure
While the motor is running, the fan lock signal remains HIGH for a predetermined number of times in a row.
Causes: • Take-up cooling fan (FM1) • DF control board (DFCB)
Remedy: 1 Check the connector of FM1-DFCB CN9 for proper connection and correct as necessary. 2 Check the fan for possible overload and correct as necessary. 3 FM1 operation check DFCB CN9-9 (LOCK) DF-702 4-C. 4 Replace FM1. 5 DFCB ICP5 conduction check. 6 Replace DFCB.

Code: C8401

Description: Data flash failure
Data flash does not access normally
Causes: DF control board (DFCB)
Remedy: 1 Turn OFF the main power switch, disconnect and then connect the power cord. Wait for 10 sec. or more after connect the power cord, and turn ON the main power switch. 2 Check the DFCB connector for proper connection and correct as necessary. 3 Rewrite the firmware. 4 Replace DFCB.

Code: C9401

Description: Exposure LED lighting failure
The output from the CCD sensor is a predetermined value or less during CCD sensor gain adjustment.
Causes: • LED exposure unit (LA201) • Flat cable • CCD board (CCDB) • Scanner drive board (SCDB) • MFP board (MFPB)
Remedy: 1 Check the connection between SCDB and LA201, and correct if necessary. 2 Check the connection between SCDB and MFPB, and correct if necessary. 3 Check that the connection between CCDB and MFPB, and correct if necessary. 4 Replace the LED exposure unit. 5 Replace CCDB. 6 SCDB F1 conduction check. 7 Replace SCDB. 8 Replace MFPB.

Code: C9402

Description: Exposure LED lighting abnormally
The average output value of the CCD sensor with the scanner at its standby position is a predetermined value or more at the end of a scan job.
Causes: • LED exposure unit (LA201) • Flat cable • CCD board (CCDB) • Scanner drive board (SCDB) • MFP board (MFPB)
Remedy: 1 Check the connection between SCDB and LA201, and correct if necessary. 2 Check the connection between SCDB and MFPB, and correct if necessary. 3 Check that the connection between CCDB and MFPB, and correct if necessary. 4 Replace the LED exposure unit. 5 Replace CCDB. 6 SCDB F1 conduction check. 7 Replace SCDB. 8 Replace MFPB.

Code: C9403

Description: CIS LED lighting failure
At the CIS gain adjustment, the machine detected that the output of the CIS LED is lower than the specified value.
Causes: • CIS module (CIS) • DF power supply (DFPU) • Dual scan image processing board (DSIPB) • MFP board (MFPB)
Remedy: 1 Correct the harness connection between CIS and DSIPB if faulty. 2 Correct the harness connection between CIS and DFPU if faulty. 3 Replace CIS. 4 Replace DFPU. 5 Replace DSIPB. 6 Replace MFPB.

Code: C9404

Description: CIS LED lighting abnormally
After a scan job is completed, the machine detected that the average output of the CIS LED is greater than the specified value.
Causes: • CIS module (CIS) • DF power supply (DFPU) • Dual scan image processing board (DSIPB) • MFP board (MFPB)
Remedy: 1 Correct the harness connection between CIS and DSIPB if faulty. 2 Correct the harness connection between CIS and DFPU if faulty. 3 Replace CIS. 4 Replace DFPU. 5 Replace DSIPB. 6 Replace MFPB.

Code: CA051

Description: Standard controller configuration failure
The controller of the MFP board (MFPB) is faulty.
Causes: MFP board (MFPB)
Remedy: 1 Check to see if the following setting has been correctly made: [Service Mode] - [System 2] - [Image Controller Setting]. If changing the setting, turn OFF the main power switch and turn it ON again after 10 seconds or more. 2 Check the connectors of the MFP board (MFPB) for proper connection and correct as necessary. 3 Replace MFPB.

Code: CA052

Description: Controller hardware error
A controller hardware error is detected in the network I/F.
Causes: MFP board (MFPB)
Remedy: 1 Check to see if the following setting has been correctly made: [Service Mode] - [System 2] - [Image Controller Setting]. If changing the setting, turn OFF the main power switch and turn it ON again after 10 seconds or more. 2 Check the connectors of the MFP board (MFPB) for proper connection and correct as necessary. 3 Replace MFPB.