Các lỗi thường gặp

Code :
  • Code: CD202
  • Description: Memory capacity discrepancy. • File memory capacity on the printer control board (PRCB) is not enough. • File memory capacity necessary for duplex printing is not enough during duplex unit mounting.
  • Causes: • MFP board (MFPB) • Memory
  • Remedy: 1 Check to see if the memory on MFPB is installed correctly. - - 2 Replace the memory on MFPB. - - 3 Replace MFPB
  • Code: CD203
  • Description: Memory capacity discrepancy 2. File memory capacity on the printer control board (PRCB) is not enough.
  • Causes: • MFP board (MFPB) • Memory
  • Remedy: 1 Check to see if the memory on MFPB is installed correctly. - - 2 Replace the memory on MFPB. - - 3 Replace MFPB
  • Code: CD211
  • Description: PCI-SDRAM DMA operation failure. Hardware related to the transfer of memory image of the printer control board (PRCB) fails to respond.
  • Causes: MFP board (MFPB)
  • Remedy: 1 Replace MFPB
  • Code: CD212
  • Description: Compression/extraction timeout detection. Hardware related to the BTC compression function of the printer control board (PRCB) fails to respond.
  • Causes: MFP board (MFPB)
  • Remedy: 1 Replace MFPB
  • Code: CD241, CD242
  • Description: Encryption ASIC error. Encryption ASIC mounting error.
  • Causes: MFP board (MFPB)
  • Remedy: 1 Check the MFP board connector for proper connection and correct as necessary. - - 2 Replace MFPB
  • Code: CD252
  • Description: No relay circuit boards for IC-414 mounting at IC-414 mount setting. EFI relay board (EFIRYB; VI-506) are not mounted when the IC-414 is set to mount setting at Service Mode.
  • Causes: • MFP board (MFPB) • EFI relay board (EFIRYB; VI-506)
  • Remedy: 1 If the IC-414 is not mounted, access [Service Mode] -> [System 2] -> [Image Controller Setting] and check to see if "Controller 0" is set for [Image Controller Setting]. - - 2 Check the EFI relay board (EFIRYB; VI-506) connector for proper connection and correct as necessary. - - 3 Replace the EFI relay board (EFIRYB; VI-506) - - 4 Replace MFPB
  • Code: CD261
  • Description: USB host board failure. • When a failure is detected in USB host board included in the local interface kit. • Non-standard USB device is connected.
  • Causes: • MFP board (MFPB) • USB host board (EK-604)
  • Remedy: 1 Check the operation with another USB device. - - 2 Check the USB host board connector for proper connection and correct as necessary. - - 3 Replace the USB host board. - - 4 Replace MFPB.
  • Code: CD271
  • Description: i-Option activated and additional memory not installed. While the i-Option is activated, the additional memory included in UK-204 is not installed.
  • Causes: • MFP board (MFPB) • Memory board/2 (MEMB/2; UK-204)
  • Remedy: 1 Check the memory board/2 (MEMB/2; UK-204) for proper connection and correct as necessary. - - 2 Replace the memory board/2 (MEMB/2; UK-204) - - 3 Replace MFPB