Description: Fusing Drive Motor turning at abnormal timing
• The Motor Lock signal remains LOW for a predetermined continuous period of time while the Motor remains stationary.
Description: 2nd Image Transfer Roller pressure/retraction failure
• The 2nd Image Transfer Pressure Position Sensor is not activated (retracted position) within 2 sec. after the 2nd Image Transfer Pressure/Retraction Motor has started turning during a sequence of the 2nd Image Transfer Roller's retracting motion. • The 2nd Image Transfer Pressure Position Sensor is not deactivated (pressed position) within 2 sec. after the 2nd Image Transfer Pressure/Retraction Motor has started turning during a sequence of the 2nd Image Transfer Roller's pressing motion.
Remedy: 1 Check the M13 connector for proper connection and correct as necessary. 2 PC29 I/O check PWB-MC PJ12MC-9A (ON) 6-B. 3 M13 operation check PWB-MC PJ18MC-1 (REM) 6-A. 4 Change PWB-MC.
Code: C0096
Description: Image Transfer Belt pressure/ retraction failure
• The 1st Image Transfer Retraction Position Sensor is not activated (retracted position) within 5 sec. after the 1st Image Transfer Pressure/Retraction Motor has started turning during a sequence of the Transfer Belt's retracting motion. • The 1st Image Transfer Retraction Position Sensor is not deactivated (pressed position) within 1 sec. after the 1st Image Transfer Pressure/Retraction Motor has started turning during a sequence of the Transfer Belt's pressing motion.
Remedy: 1 Check the M11 connector for proper connection and correct as necessary. 2 PC12 I/O check PWB-MC PJ3MC-6B (ON) 6-B. 3 M11 operation check PWB-MC PJ5MC-1~4 (Pulse Output) 6-C. 4 Change PWB-MC.
Code: C0098
Description: Fusing Pressure Roller pressure/ retraction failure
• No change is observed in the encoder sensor pulse even after the lapse of 0.5 sec. after the Fusing Pressure/Retraction Motor has started turning for a sequence of the Fusing Pressure Roller’s retracting motion. • No change is observed in the encoder sensor pulse even after the lapse of 0.5 sec. after the Fusing Pressure/Retraction Motor has started turning for a sequence of the Fusing Pressure Roller’s pressing motion. • The Fusing Pressure Position Sensor is not activated (pressed position) even when 30 encoder sensor pulses are counted after the Fusing Pressure/Retraction Motor has started turning for a sequence of the Fusing Pressure Roller’s pressing motion.
Remedy: 1 Check the M9 connector for proper connection and correct as necessary. 2 PC33 I/O check PWB-MC PJ7MC-12A (ON) 2-M. 3 PC34 operation check PWB-MC PJ16MC-3A (Pulse Output) 16-P. 4 M19 operation check PWB-MC PJ19MC-5B,6B (Pulse Output) 2-J. 5 Change Fusing Unit. 6 Change PWB-MC.
Code: C0200
Description: Cyan PC Drum Charge Corona malfunction
• An output is automatically produced from the PC Drum Charge Corona of each color when the malfunction resetting procedure is performed after C0208 (PC Drum Charge Corona malfunction) has been detected. The SCD signal is detected for a continuous 0.5-sec. period at this time.
Remedy: 1 Check the Imaging Unit contact and correct or clean as necessary. 2 Check the HV1 contact and correct or clean as necessary. 3 Change Imaging Unit. 4 Change HV1. 5 Change PWB-MC.
Code: C0202
Description: Magenta PC Drum Charge Corona malfunction
Remedy: 1 Check the Imaging Unit contact and correct or clean as necessary. 2 Check the HV1 contact and correct or clean as necessary. 3 Change Imaging Unit. 4 Change HV1. 5 Change PWB-MC.
Code: C0204
Description: Yellow PC Drum Charge Corona malfunction
Remedy: 1 Check the Imaging Unit contact and correct or clean as necessary. 2 Check the HV1 contact and correct or clean as necessary. 3 Change Imaging Unit. 4 Change HV1. 5 Change PWB-MC.
Code: C0206
Description: Black PC Drum Charge Corona malfunction
Remedy: 1 Check the Imaging Unit contact and correct or clean as necessary. 2 Check the HV1 contact and correct or clean as necessary. 3 Change Imaging Unit. 4 Change HV1. 5 Change PWB-MC.