Description: When the sub power switch (SW2) turns ON, ISW unwritten area is detected in the LS firmware (1st tandem).
Causes: • LSCB firmware • LS control board (LSCB)
Remedy: 1. Reinstall the LSCB firmware. 2. Check the connector connection and the wiring between the main body and each option, and repair it if any abnormality. 3. Check the I/F connector connection and the wiring for ISW on RBU, and repair it if any abnormality. 4. Check the connector connection and the wiring between RUB and OACB, and repair it if any abnormality. 5. Replace LSCB.
Code: C-C112
Description: When the sub power switch (SW2) turns ON, ISW unwritten area is detected in the LS firmware (2nd tandem).
Causes: • LSCB firmware • LS control board (LSCB)
Remedy: 1. Reinstall the LSCB firmware. 2. Check the connector connection and the wiring between the main body and each option, and repair it if any abnormality. 3. Check the I/F connector connection and the wiring for ISW on RBU, and repair it if any abnormality. 4. Check the connector connection and the wiring between RUB and OACB, and repair it if any abnormality. 5. Replace LSCB.
Code: C-C113
Description: When the sub power switch (SW2) turns ON, ISW unwritten area is detected in the FD firmware.
Causes: • FDCB firmware • FD control board (FDCB)
Remedy: 1. Reinstall the FDCB firmware. 2. Check the connector connection and the wiring between the main body and each option, and repair it if any abnormality. 3. Check the I/F connector connection and the wiring for ISW on RBU, and repair it if any abnormality. 4. Check the connector connection and the wiring between RUB and OACB, and repair it if any abnormality. 5. Replace FDCB.
Code: C-C114
Description: When the sub power switch (SW2) turns ON, ISW unwritten area is detected in the SD firmware.
Causes: • SDCB firmware • SD control board (SDCB)
Remedy: 1. Reinstalling SDCB firmware 2. Check the connector connection and the wiring between the main body and each option, and repair it if any abnormality. 3. Check the I/F connector connection and the wiring for ISW on RBU, and repair it if any abnormality. 4. Check the connector connection and the wiring between RUB and OACB, and repair it if any abnormality. 5. Replace SDCB.
Code: C-C116
Description: When the sub power switch (SW2) turns ON, ISW unwritten area is detected in the PB firmware.
Causes: • PB firmware • PB control board (PBCB)
Remedy: 1. Reinstalling PBCB firmware 2. Check the connector connection and the wiring between the main body and each option, and repair it if any abnormality. 3. Check the I/F connector connection and the wiring for ISW on RBU, and repair it if any abnormality. 4. Check the connector connection and the wiring between RUB and OACB, and repair it if any abnormality. 5. Replace PBCB.
Code: C-C117
Description: When the sub power switch (SW2) turns ON, ISW unwritten area is detected in the GP firmware.
Causes: • GP firmware • Punch Controller PCB
Remedy: 1. Reinstall the GP firmware. 2. Check the connector connection and the wiring between the main body and each option, and repair it if any abnormality. 3. Check the I/F connector connection and the wiring for ISW on RBU, and repair it if any abnormality. 4. Check the connector connection and the wiring of RBU, OB4 and OACB, and repair it if any abnormality. 5. Replace punch controller PCB.
Code: C-C118
Description: When the sub power switch (SW2) turns ON, ISW unwritten area is detected in the RU firmware.
Causes: • Firmware of RUCB • RU control board (RUCB)
Remedy: 1. Reinstall the RUCB firmware. 2. Check the connector connection and the wiring between the main body and each option, and repair it if any abnormality. 3. Check the I/F connector connection and the wiring for ISW on RBU, and repair it if any abnormality. 4. Check the connector connection and the wiring between RBU and OACB, and repair it if any abnormality. 5. Replace RUCB
Code: C-C119
Description: When the sub power switch (SW2) turns ON, ISW unwritten area is detected in the RU program.
Causes: • RU firmware • RU control board (RUCB)
Remedy: 1. Reinstall the RU firmware. 2. Check the connector connection and the wiring between the main body and each option, and repair it if any abnormality. 3. Check the I/F connector connection and the wiring for ISW on RBU, and repair it if any abnormality. 4. Check the connector connection and the wiring between RUB and OACB, and repair it if any abnormality. 5. Replace RUCB