Description: The blowout of a 5V fuse for the AC drive board (ACDB) is checked. In the serial initial communication, a signal of the blowout of a 5V fuse (AC drive) is detected.
Causes: AC drive board (ACDB)
Remedy: The main body stops immediately to turn OFF the RL1 (main).
Description: The blowout of a SD/CL fuse in the tray is detected 1. The 24V power source for the SD/CL in the printer control board (PRCB) is checked. At the start, an error detection signal (blowout of a fuse for the solenoid/clutch) is detected, and an error detection signal (24V cut off) is also detected.
Causes: DC power supply /1 (DCPS/ 1)
Remedy: The main body stops immediately to turn OFF the RL1 (main).
Description: The blowout of a SD/CL fuse in the tray is detected 2. The blowout of a fuse for the SD/CL in the printer control board (PRCB) is checked. At the start, an error detection signal (blowout of a fuse for the solenoid/clutch) is detected. However, an error detection signal (24V cut off) is not detected.
Causes: Paper feed clutch /1 (CL4), / 2 (CL6) Separation clutch /1 (CL5), / 2 (CL7) Printer control board (PRCB)
Remedy: The main body stops immediately to turn OFF the RL1 (main).
Description: The blowout of a fuse for the SD/ CL in the vertical conveyance is detected 1. The 24V power source for the SD/CL in the printer control board (PRCB) is checked. At the start, an error detection signal (blowout of a fuse for the solenoid/ clutch) is detected, and an error detection signal (24V cut off) is detected.
Causes: DC power supply /1 (DCPS/ 1)
Remedy: The main body stops immediately to turn OFF the RL1 (main).
Description: The blowout of a fuse for the SD/ CL in the vertical conveyance is detected 2. The blowout of a fuse for the SD/CL in the printer control board (PRCB) is checked. At the start, an error detection signal (blowout of a fuse for the solenoid/ clutch) is detected. However, an error detection signal (24V cut off) is not detected.
Description: The blowout of a fuse for the SD/ CL in the PF is detected 1. The 24V power source for the SD/CL in the PF drive board (PFUCB) is checked. At the start, an error detection signal (blowout of a fuse for the solenoid/clutch) is detected, and an error detection signal (24V cut off) is detected.
Causes: PF drive board (PFUDB)
Remedy: The main body stops immediately to turn OFF the RL1 (main).
Description: The blowout of a fuse for the SD/ CL in the PF is detected 2. The blowout of a fuse for the SD/CL in the PF drive board (PFUDB) is checked. At the start, an error detection signal (blowout of a fuse for the solenoid/motor) is detected. However, an error detection signal (24V cut off) is not detected.
Causes: PF drive board (PFUDB)
Remedy: The main body stops immediately to turn OFF the RL1 (main).
Nhận ưu đãi sớm nhất khi chương trình diễn ra
Đăng ký nhận bản tin
Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này.
Chính sách cookie
Những cookie này là cần thiết để trang web hoạt động đúng cách.
Những cookie này giúp chúng tôi hiểu cách khách truy cập tương tác với trang web.
Những cookie này được sử dụng để cung cấp quảng cáo cá nhân hóa.