Các lỗi thường gặp

Code :
  • Code: SC29-14
  • Description: Auto adjustment monitor value abnormality. No convergence is made in the auto adjustment of the separation (DC) current.
  • Causes: High voltage unit /2 (HV2)
  • Remedy: Error codes are not displayed on the operation board, but displayed only on the data collection, the list output and the CSRC. The control of the main body is made by using a data previously obtained.
  • Code: SC29-15
  • Description: Auto adjustment monitor value abnormality. No convergence is made in the auto adjustment of the developing bias.
  • Causes: High voltage unit /1 (HV1)
  • Remedy: Error codes are not displayed on the operation board, but displayed only on the data collection, the list output and the CSRC. The control of the main body is made by using a data previously obtained.
  • Code: SC29-16
  • Description: Drum charger capacity deterioration abnormality. When the charger grid/developing bias is in excess of the limit of correction, lower the developing potential/ fogging margin potential in steps of 50V. And as a result, less than 50V of the difference with the target charger potential is detected 10 times in succession.
  • Causes: Drum Drum potential sensor (DPS)
  • Remedy: The main body stops immediately to turn OFF the RL1 (main).
  • Code: SC32-01
  • Description: The rotation of the IPB cooling fan (FM12) is checked, and the 24V power source is also checked. An abnormal signal condition occurs a specified period of time after the FM12 is turned ON. This abnormal condition recurs even a specified period of time after the FM12 is turned OFF and then turned ON, and an error detection signal (24V cut off) is detected.
  • Causes: DC power supply /1 (DCPS/ 1)
  • Remedy: The main body stops immediately to turn OFF the RL1 (main).
  • Code: SC32-02
  • Description: The blowout of a fuse for the IPB cooling fan (FM12) in the AC drive board (ACDB) is checked. An abnormal condition occurs with the FM12 EM signal a specified period of time after the FM12 is turned ON. This abnormal condition recurs even a specified period of time after the FM12 is turned OFF and then turned ON, and an error detection signal (blowout of a fuse) is detected with the 24V normal.
  • Causes: AC drive board (ACDB) IPB cooling fan (FM12)
  • Remedy: The main body stops immediately to turn OFF the RL1 (main).
  • Code: SC32-03
  • Description: The rotation of the IPB cooling fan (FM12) is checked. An abnormal condition occurs with the FM12 EM signal a specified period of time after the FM12 is turned ON. This abnormal condition recurs even a specified period of time after the FM12 is turned OFF and then turned ON, and an error detection signal (24V cut off/blowout of a fuse) is not detected.
  • Causes: AC drive board (ACDB) IPB cooling fan (FM12)
  • Remedy: The main body stops immediately to turn OFF the RL1 (main).
  • Code: SC32-04
  • Description: When the print is started, the EM signal of the PB cooling fan (FM12) turns ON.
  • Causes: AC drive board (ACDB) IPB cooling fan (FM12)
  • Remedy: Error codes are not displayed on the operation board, but displayed only on the data collection, the list output and the CSRC. The control of the main body is made by using a data previously obtained.
  • Code: SC32-05
  • Description: The rotation of the pump cooling fan (FM11) is checked, and the 24V power source is also checked. An abnormal condition occurs with the FM11 EM signal a specified period of time after the FM11 is turned ON. This abnormal condition recurs even a specified period of time after the FM11 is turned OFF and then turned ON, and an error detection signal (24V cut off) is detected.
  • Causes: DC power supply /2 (DCPS/ 2)
  • Remedy: The main body stops immediately to turn OFF the RL1 (main).