Các lỗi thường gặp

Code :
  • Code: C-1514
  • Description: Clamp rotation motor (M23) drive abnormality. The rotation of the clamp section has not been completed within a specified period of time after M23 turns ON. 35-4
  • Causes: Clamp rotation motor (M23: PB-502, PB-503) PB drive board (PBDB: PB-502) PB drive board /1 (PBDB1: PB-503) PB control board (PBCB: PB-502, PB-503)
  • Remedy: 1 Check the clamp section, and clean/repair it if any abnormality. - 2 Check the connector connection and the wiring between PBDB/PBDB1 and the motor, and repair it if any abnormality. - 3 Check the connector connection and the wiring between PBDB/PBDB1 and PBCB, and repair it if any abnormality. - 4 Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. PB-502: 8-D PB-503: 8-D 5 Replace M23. - 6 Replace PBDB (PB-502), PBDB1 (PB-503). - 7 Replace PBCB.
  • Code: C-1515
  • Description: Glue tank movement motor (M31) drive abnormality. The movement of the glue tank has not been completed within a specified period of time after M31 turns ON. 35-4
  • Causes: Glue tank movement motor (M31: PB-502, PB-503) PB drive board (PBDB: PB-502) PB drive board /1 (PBDB1: PB-503) PB control board (PBCB: PB-502, PB-503)
  • Remedy: 1 Check the glue tank movement section, and clean/repair it if any abnormality. - 2 Check the connector connection and the wiring between PBDB/PBDB1 and the motor, and repair it if any abnormality. - 3 Check the connector connection and the wiring between PBDB/PBDB1 and PBCB, and repair it if any abnormality. - 4 Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. PB-502: 8-D PB-503: 8-D 5 Replace M31. - 6 Replace PBDB (PB-502), PBDB1 (PB-503). - 7 Replace PBCB.
  • Code: C-1516
  • Description: Glue apply roller motor (M32) drive abnormality. An error detection signal is detected continuously for a specified time period while the M32 is driving. 35-4
  • Causes: Glue apply roller motor (M32: PB-502, PB-503) PB drive board (PBDB: PB-502) PB drive board /1 (PBDB1: PB-503) PB control board (PBCB: PB-502, PB-503)
  • Remedy: 1 Check the glue apply section, and clean/repair it if any abnormality. - 2 Check the connector connection and the wiring between PBDB/PBDB1 and the motor, and repair it if any abnormality. - 3 Check the connector connection and the wiring between PBDB/PBDB1 and PBCB, and repair it if any abnormality. - 4 Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. PB-502: 9-D PB-503: 9-D 5 Replace M32. - 6 Replace PBDB (PB-502), PBDB1 (PB-503). - 7 Replace PBCB.
  • Code: C-1517
  • Description: PB-502: Abnormality of the glue supply. The count of a specified number of pellets, which is counted by the pellet count sensor (PS37), has not been reached after the pellet supply motor (M33) turns ON. The status was detected by a specified number of times in succession. PB-503: Abnormality of the glue supply. The supply operation which the pellet supply passage sensor (PS37) does not turn ON is detected twice in succession after turning ON the pellet supply pipe motor (M33). 35-4
  • Causes: Pellet supply motor (M33: PB-502) PB drive board (PBDB: PB-502) PB drive board /1 (PBDB1: PB-503) PB control board (PBCB: PB-502, PB-503)
  • Remedy: 1 Check the pellet supply section, and clean/repair it if any abnormality. - 2 Check the connector connection and the wiring between PBDB/PBDB1 and the motor, and repair it if any abnormality. - 3 Check the connector connection and the wiring between PBDB/PBDB1 and PBCB, and repair it if any abnormality. - 4 Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. PB-502: 10-D PB-503: 10-D 5 Replace M33. - 6 Replace PBDB (PB-502), PBDB1 (PB-503). - 7 Replace PBCB.
  • Code: C-1518
  • Description: Pellet supply arm motor (M34) drive abnormality. The movement of the pellet supply arm has not been completed within a specified period of time after M34 turns ON. 35-4
  • Causes: Pellet supply arm motor (M34: PB-502, PB-503) PB drive board (PBDB: PB-502) PB drive board /1 (PBDB1: PB-503) PB control board (PBCB: PB-502, PB-503)
  • Remedy: 1 Check the pellet supply section, and clean/repair it if any abnormality. - 2 Check the connector connection and the wiring between PBDB/PBDB1 and the motor, and repair it if any abnormality. - 3 Check the connector connection and the wiring between PBDB/PBDB1 and PBCB, and repair it if any abnormality. - 4 Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. PB-502: 10-D PB-503: 10-D 5 Replace M34. - 6 Replace PBDB (PB-502), PBDB1 (PB-503). - 7 Replace PBCB.
  • Code: C-1519
  • Description: Cover paper alignment motor (M41) drive abnormality. The alignment of the up/down cover paper has not been completed within a specified period of time after M41 turns ON. 35-4
  • Causes: Cover paper alignment motor (M41: PB-502, PB- 503) PB drive board (PBDB: PB-502) PB drive board /1 (PBDB1: PB-503) PB control board (PBCB: PB-502, PB-503)
  • Remedy: 1 Check the cover paper alignment section, and clean/repair it if any abnormality. - 2 Check the connector connection and the wiring between PBDB/PBDB1 and the motor, and repair it if any abnormality. - 3 Check the connector connection and the wiring between PBDB/PBDB1 and PBCB, and repair it if any abnormality. - 4 Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. PB-502: 12-D PB-503: 12-D 5 Replace M41. - 6 Replace PBDB (PB-502), PBDB1 (PB-503). - 7 Replace PBCB.
  • Code: C-1520
  • Description: Booklet exit motor (M42) drive abnormality. The booklet exit has not been completed within a specified period of time after M42 turns ON. 35-4
  • Causes: Booklet exit motor (M42: PB-502, PB-503) PB drive board (PBDB: PB-502) PB drive board /1 (PBDB1: PB-503) PB control board (PBCB: PB-502, PB-503)
  • Remedy: 1 Check the booklet exit section, and clean/repair it if any abnormality. - 2 Check the connector connection and the wiring between PBDB/PBDB1 and the motor, and repair it if any abnormality. - 3 Check the connector connection and the wiring between PBDB/PBDB1 and PBCB, and repair it if any abnormality. - 4 Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. PB-502: 12-D PB-503: 12-D 5 Replace M42. - 6 Replace PBDB (PB-502), PBDB1 (PB-503). - 7 Replace PBCB.
  • Code: C-1521
  • Description: Cover paper conveyance arm motor /Rt (M43) drive abnormality. The driven arm /Rt shaking operation start has not been completed within a specified period of time after M43 turns ON. 35-4
  • Causes: Cover paper conveyance arm motor /Rt (M43: PB- 502, PB-503) PB drive board (PBDB: PB-502) PB drive board /1 (PBDB1: PB-503) PB control board (PBCB: PB-502, PB-503)
  • Remedy: 1 Check the cover paper conveyance section, and clean/repair it if any abnormality. - 2 Check the connector connection and the wiring between PBDB/PBDB1 and the motor, and repair it if any abnormality. - 3 Check the connector connection and the wiring between PBDB/PBDB1 and PBCB, and repair it if any abnormality. - 4 Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. PB-502: 12-D PB-502: 12-D 5 Replace M43. - 6 Replace PBDB (PB-502), PBDB1 (PB-503). - 7 Replace PBCB.