Các lỗi thường gặp

Code :
  • Code: C-1506
  • Description: SC switchback release motor (M13) drive abnormality. The switchback roller release operation has not been completed within a specified period of time after M13 turns ON. 35-4
  • Causes: SC switchback release motor (M13: PB-502, PB- 503) PB drive board (PBDB: PB-502) PB drive board /1 (PBDB1: PB-503) PB control board (PBCB: PB-502, PB-503)
  • Remedy: 1 Check the SC switchback release section, and clean/repair it if any abnormality. - 2 Check the connector connection and the wiring between PBDB/PBDB1 and the motor, and repair it if any abnormality. - 3 Check the connector connection and the wiring between PBDB/PBDB1 and PBCB, and repair it if any abnormality. - 4 Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. PB-502: 6-D PB-503: 6-D 5 Replace M13. - 6 Replace PBDB (PB-502), PBDB1 (PB-503). - 7 Replace PBCB.
  • Code: C-1507
  • Description: SC alignment motor (M15) drive abnormality. The SC alignment has not been completed within a specified period of time after M15 turns ON. 35-4
  • Causes: SC alignment motor (M15: PB-502, PB-503) PB drive board (PBDB: PB-502) PB drive board /1 (PBDB1: PB-503) PB control board (PBCB: PB-502, PB-503)
  • Remedy: 1 Check the SC alignment section, and clean/repair it if any abnormality. - 2 Check the connector connection and the wiring between PBDB/PBDB1 and the motor, and repair it if any abnormality. - 3 Check the connector connection and the wiring between PBDB/PBDB1 and PBCB, and repair it if any abnormality. - 4 Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. PB-502: 5-D PB-503: 5-D 5 Replace M15. - 6 Replace PBDB (PB-502), PBDB1 (PB-503). - 7 Replace PBCB. -
  • Code: C-1508
  • Description: SC bundle conveyance motor (M17) drive abnormality. The SC paper bundle conveyance has not been completed within a specified period of time after M17 turns ON. 35-4
  • Causes: SC bundle conveyance motor (M17: PB-502, PB- 503) PB drive board (PBDB: PB-502) PB drive board /1 (PBDB1: PB-503) PB control board (PBCB: PB-502, PB-503)
  • Remedy: 1 Check the SC bundle conveyance section, and clean/repair it if any abnormality. - 2 Check the connector connection and the wiring between PBDB/PBDB1 and the motor, and repair it if any abnormality. - 3 Check the connector connection and the wiring between PBDB/PBDB1 and PBCB, and repair it if any abnormality. - 4 Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. PB-502: 5-D PB-503: 5-D 5 Replace M17. - 6 Replace PBDB (PB-502), PBDB1 (PB-503). - 7 Replace PBCB.
  • Code: C-1509
  • Description: SC roller release motor (M18) drive abnormality. The SC roller release operation has not been completed within a specified period of time after M18 turns ON. 35-4
  • Causes: SC roller release motor (M18: PB-502, PB-503) PB drive board (PBDB: PB-502) PB drive board /1 (PBDB1: PB-503) PB control board (PBCB: PB-502, PB-503)
  • Remedy: 1 Check the SC roller release section, and clean/repair it if any abnormality. - 2 Check the connector connection and the wiring between PBDB/PBDB1 and the motor, and repair it if any abnormality. - 3 Check the connector connection and the wiring between PBDB/PBDB1 and PBCB, and repair it if any abnormality. - 4 Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. PB-502: 6-D PB-503: 6-D 5 Replace M18. - 6 Replace PBDB (PB-502), PBDB1 (PB-503). - 7 Replace PBCB.
  • Code: C-1510
  • Description: Clamp entrance movement motor (M19) drive abnormality. The movement of the SC entrance has not been completed within a specified period of time after M19 turns ON. 35-4
  • Causes: Clamp entrance movement motor (M19: PB-502, PB-503) PB drive board (PBDB: PB-502) PB drive board /1 (PBDB1: PB-503) PB control board (PBCB: PB-502, PB-503)
  • Remedy: 1 Check the clamp entrance section, and clean/repair it if any abnormality. - 2 Check the connector connection and the wiring between PBDB/PBDB1 and the motor, and repair it if any abnormality. - 3 Check the connector connection and the wiring between PBDB/PBDB1 and PBCB, and repair it if any abnormality. - 4 Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. PB-502: 5-D PB-503: 5-D 5 Replace M19. - 6 Replace PBDB (PB-502), PBDB1 (PB-503). - 7 Replace PBCB.
  • Code: C-1511
  • Description: Clamp entrance roller release motor (M20) drive abnormality. The SC entrance roller release operation has not been completed within a specified period of time after M20 turns ON. 35-4
  • Causes: Clamp entrance roller release motor (M20: PB-502, PB-503) PB drive board (PBDB: PB-502) PB drive board /1 (PBDB1: PB-503) PB control board (PBCB: PB-502, PB-503)
  • Remedy: 1 Check the clamp entrance section, and clean/repair it if any abnormality. - 2 Check the connector connection and the wiring between PBDB/PBDB1 and the motor, and repair it if any abnormality. - 3 Check the connector connection and the wiring between PBDB/PBDB1 and PBCB, and repair it if any abnormality. - 4 Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. PB-502: 7-D PB-503: 7-D 5 Replace M20. - 6 Replace PBDB (PB-502), PBDB1 (PB-503). - 7 Replace PBCB.
  • Code: C-1512
  • Description: Clamp alignment motor (M21) drive abnormality. The SC alignment has not been completed within a specified period of time after M21 turns ON. 35-4
  • Causes: Clamp alignment motor (M21: PB-502, PB-503) PB drive board (PBDB: PB-502) PB drive board /1 (PBDB1: PB-503) PB control board (PBCB: PB-502, PB-503)
  • Remedy: 1 Check the clamp alignment section, and clean/repair it if any abnormality. - 2 Check the connector connection and the wiring between PBDB/PBDB1 and the motor, and repair it if any abnormality. - 3 Check the connector connection and the wiring between PBDB/PBDB1 and PBCB, and repair it if any abnormality. - 4 Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. PB-502: 7-D PB-503: 7-D 5 Replace M21. - 6 Replace PBDB (PB-502), PBDB1 (PB-503). - 7 Replace PBCB.
  • Code: C-1513
  • Description: Clamp motor (M22) drive abnormality. The open/close process of the clamp section has not been completed within a specified period of time after M22 turns ON. 35-4
  • Causes: Clamp motor (M22: PB-502, PB-503) PB drive board (PBDB: PB-502) PB drive board /1 (PBDB1: PB-503) PB control board (PBCB: PB-502, PB-503)
  • Remedy: 1 Check the clamp section, and clean/repair it if any abnormality. - 2 Check the connector connection and the wiring between PBDB/PBDB1 and the motor, and repair it if any abnormality. - 3 Check the connector connection and the wiring between PBDB/PBDB1 and PBCB, and repair it if any abnormality. - 4 Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. PB-502: 8-D PB-503: 8-D 5 Replace M22. - 6 Replace PBDB (PB-502), PBDB1 (PB-503). - 7 Replace PBCB.