Description: FD operation prohibition abnormality When the FD is unready, a signal to start operations is received from the main body.
Causes: FD control board (FDCB: FD-503)
Remedy: 1 After turning OFF the sub power switch, turn OFF the main power switch and unplug the power plug. Restart the main body after 10 seconds. - 2 Check the connector connection and the wiring of FDCB, and repair it if any abnormality. - 3 Reinstalling FD firmware - 4 Replace FDCB.
Description: SD operation prohibition abnormality When the SD is unready, a signal to start operations is received from the main body.
Causes: SD control board (SDCB: SD-506)
Remedy: 1 After turning OFF the sub power switch, turn OFF the main power switch and unplug the all power plugs. Restart the main body after 10 seconds. - 2 Check the connector connection and the wiring of SDCB, and repair it if any abnormality. - 3 Reinstalling SD firmware - 4 Replace SDCB.
Description: RU operation prohibition abnormality When RU is unready, a signal to start operations is received from the main body.
Causes: RU control board (RUCB: RU-506)
Remedy: 1 After turning OFF the sub power switch, turn OFF the main power switch and unplug the power plug. Restart the main body after 10 seconds. - 2 Check the connector connection and the wiring of RUCB, and repair it if any abnormality. - 3 Reinstalling RU firmware - 4 Replace RUCB
Description: PB operation prohibition abnormality When PB is unready, a signal to start operations is received from the main body.
Causes: PB control board (PBCB: PB-502, PB-503)
Remedy: 1 After turning OFF the sub power switch, turn OFF the main power switch and unplug the all power plugs. Restart the main body after 10 seconds. - 2 Check the connector connection and the wiring of PBCB, and repair it if any abnormality. - 3 Reinstalling PB firmware - 4 Replace PBCB.
Description: Entrance conveyance motor (M1) drive abnormality. The entrance conveyance has not been completed within a specified period of time after M1 turns ON. 35-5
Remedy: 1 Check the entrance conveyance section, and clean/repair it if any abnormality. - 2 Check the connector connection and the wiring between PBDB/PBDB1 and the motor, and repair it if any abnormality. - 3 Check the connector connection and the wiring between PBDB/PBDB1 and PBCB, and repair it if any abnormality. - 4 Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. PB-502: 1-D PB-503: 1-D 5 Replace M1. - 6 Replace PBDB (PB-502), PBDB1 (PB-503). - 7 Replace PBCB.
Description: Intermediate conveyance motor (M2) drive abnormality. An error detection signal is detected continuously for a specified time period while the M2 is driving. 35-4
Remedy: 1 Check the intermediate conveyance section, and clean/repair it if any abnormality. - 2 Check the connector connection and the wiring between PBDB/PBDB1 and the motor, and repair it if any abnormality. - 3 Check the connector connection and the wiring between PBDB/PBDB1 and PBCB, and repair it if any abnormality. - 4 Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. PB-502: 2-D PB-503: 2-D 5 Replace M2. - 6 Replace PBDB (PB-502), PBDB1 (PB-503). - 7 Replace PBCB.
Description: SC entrance conveyance motor (M11) drive abnormality. The SC entrance conveyance has not been completed within a specified period of time after M11 turns ON. 35-4
Remedy: 1 Check the SC entrance conveyance section, and clean/repair it if any abnormality. - 2 Check the connector connection and the wiring between PBDB/PBDB1 and the motor, and repair it if any abnormality. - 3 Check the connector connection and the wiring between PBDB/PBDB1 and PBCB, and repair it if any abnormality. - 4 Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. PB-502: 4-D PB-503: 4-D 5 Replace M11. - 6 Replace PBDB (PB-502), PBDB1 (PB-503). - 7 Replace PBCB.
Description: SC switchback conveyance motor (M12) drive abnormality. The switchback conveyance has not been completed within a specified period of time after M12 turns ON. 35-4
Remedy: 1 Check the SC switchback conveyance section, and clean/repair it if any abnormality. - 2 Check the connector connection and the wiring between PBDB/PBDB1 and the motor, and repair it if any abnormality. - 3 Check the connector connection and the wiring between PBDB/PBDB1 and PBCB, and repair it if any abnormality. - 4 Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. PB-502: 4-D PB-503: 4-D 5 Replace M12. - 6 Replace PBDB (PB-502), PBDB1 (PB-503). - 7 Replace PBCB.
Nhận ưu đãi sớm nhất khi chương trình diễn ra
Đăng ký nhận bản tin
Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này.
Chính sách cookie
Những cookie này là cần thiết để trang web hoạt động đúng cách.
Những cookie này giúp chúng tôi hiểu cách khách truy cập tương tác với trang web.
Những cookie này được sử dụng để cung cấp quảng cáo cá nhân hóa.